Search
8 result(s) for Standby Management Entity
-
OPC-30141 – OPC UA for PROFIenergy3.2.2.1 UntitledUntitled Standby Management comprises the services allowing the switchover of a Standby Management Entity into an Energy Saving Mode , the change from one Energy Saving Mode into another ... transition back to normal operational state. The switchover of a Standby Management Entity into an Energy Saving Mode is only possible if the Standby Management Entity is not in operation
-
OPC-30141 – OPC UA for PROFIenergy3.2.3.1 UntitledUntitled A Standby Management Entity consists of specific components or functionality of the device or server which are addressed by the Standby Management services. One device or server can have ... more than one Standby Management Entity
-
OPC-30141 – OPC UA for PROFIenergy3.2.4.1 UntitledSaving Mode is a mode of operation in which energy consumption of a Standby Management Entity is lower than in normal operational state
-
OPC-30141 – OPC UA for PROFIenergy4.1.2 Standby Managementinto an Energy Saving Mode if not in operation or engaged. If a Standby Management Entity supports more than one Energy Saving Mode (with different levels of energy consumption), transitions ... information functionality of Standby Management provides information about the current state of a Standby Management Entity , the current energy consumption, the available Energy Saving Modes and their detailed characteristics
-
OPC-30141 – OPC UA for PROFIenergydevice might support multiple EnergyStandbyManagementType Object s. Each EnergyStandbyManagementType Object represents one Standby Management Entity . By invoking the StartPause Method of the EnergyStandbyManagementType Object , Clients can initiate the transition into ... Method . Figure 7 - Structural organization of PE Energy Management related functionality Figure 8 shows the relationship between the PE Energy Management model and the other functional parts of the application
-
OPC-30141 – OPC UA for PROFIenergyEnergyStandbyManagementType The EnergyStandbyManagementType ObjectTypes provide access to the Standby Management functionality of one Standby Management Entity . Parallel access of Clients to the read only data shall be possible but write ... central time management client using a broadcast telegram to which every Standby Management Entity subscribes. The Lock Object ensures exclusive write access and Method call for one client. Write access
-
OPC-34100 – OPC UA for Energy Consumption Managementinto an Energy Saving Mode if not in operation or engaged. If a Standby Management Entity supports more than one Energy Saving Mode (with different levels of energy consumption), transitions ... information functionality of Standby Management provides information about the current state of a Standby Management Entity , the current energy consumption, the available Energy Saving Modes and their detailed characteristics
-
OPC-34100 – OPC UA for Energy Consumption Management7.2.1.1 OverviewOverview The EnergyStandbyManagementType ObjectType provides access to the Standby Management functionality of one Standby Management Entity . Parallel access of Clients to the read only data shall be possible but write ... central time management client using a broadcast telegram to which every Standby Management Entity subscribes. The Lock Object ensures exclusive write access and Method call for one Client . Write access