OPC-30143 – OPC UA for PROFINET Encoder - Part <mm>: <Part Name>interest for OPC UA Clients . Typically, the use case consists of utilization of OPC UA standard mechanisms and data processing at the Client site. Table 12 - Use Cases and related Companion ... aspect of the Information Model . Providing Variables representing the Standard Signals of the configured Standard Telegram . Providing cross-aspect References
-
OPC-30143 – OPC UA for PROFINET Encoder - Part <mm>: <Part Name>basic understanding by demonstrating the model organization using three Standard Signals transmitted with Standard Telegram 89 (See [ ENCP ], chapter 5.6.2). Figure 10 - Encoder Channel Signals and Measurements The "Position ... aspect contain the numeric representation of the "speed" and "position" Standard Signals (See [ ENCP ] Table 13) allowing Clients easy access to the numeric values
-
OPC-30143 – OPC UA for PROFINET Encoder - Part <mm>: <Part Name>7.1.1 SetApplicationTag Methoddefined in [ ENCP ], chapter 5.6.1. The supported Standard Signals are determined by the configured Standard Telegram . The Server shall provide the Variables representing the Standard Signals of the configured Standard ... current position (G1_XIST1, G1_XIST2, G1_XIST3) that are part of the configured Standard Telegram using a 0:RepresentsSameEntityAs Reference . The Velocity Variable contains the current Encoder's velocity
-
OPC-30145 – OPC UA for PROFINET Drives - Part 30145: UA CS for PROFINET Drivesinterest for OPC UA Clients . Typically, the use case consists of utilization of OPC UA standard mechanisms and data processing at the Client site. Table 13 - Use Cases and related Companion ... aspect of the Information Model . Providing Variables representing the Standard Signals of the configured Standard Telegram . Providing cross-aspect References
-
OPC-30145 – OPC UA for PROFINET Drives - Part 30145: UA CS for PROFINET Drivesgive a basic understanding by demonstrating the model organization using Standard Signals transmitted with Standard Telegram 1 (see [ PI 3172 PDP ], chapter 6.3.4.3.2 and 6.3.4.4). As described, the transmitted Signals ... given by the selection of one of the Standard Telegrams or by the setup of the free telegram configuration. Figure 11 - PROFINET Signals and Axis Object Variables The "VelocityActualValue
-
OPC-30145 – OPC UA for PROFINET Drives - Part 30145: UA CS for PROFINET Drives7.1 DriveAxisTypechapter 6.3.4.2, Table 86. The supported Standard Signals are determined by the configured Standard Telegram modular telegram configuration and may also be freely configured (see [ PI 3172 PDP ], chapter ... derived Axis/DO ObjectTypes and Table 33 ) encoded as numeric data type. If the corresponding Standard Signal is configured and its representation is provided in the PNSignals folder, the Monitoring