Search
2 result(s) for SetRampUp
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type Definitions22.3 SetRampUpSetRampUp Indication if a SetValue that is higher than the actual value shall be reached as fast as possible ( SetRampUp = 0) or within a given value change per time ... SetRampUp
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type DefinitionsFalse References Node Class BrowseName DataType TypeDefinition Other Subtype of MonitoredParameterType 0:HasComponent Variable SetRampUp 0:Double 0:AnalogItemType O, RW 0:HasComponent Variable SetRampDown 0:Double 0:AnalogItemType ... HasComponent Object ClosedLoopControl ClosedLoopControlType O The variables SetRampUp and SetRamp down, which are only readable in the MonitoredParameterType , are writable in the ControlledParameterType . If SetValue (already writeable in MonitoredParameterType