Search
7 result(s) for SetConfigurationDataCmd
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.2.4.2 EstablishConnections signatureVerifyFunctionalEntityCmd (see 6.2.4.3.3 ), ReserveCommunicationIdsCmd (see 6.2.4.3.4 ), CreateConnectionEndpointCmd (see 6.2.4.3.5 ), EstablishControlCmd (see 6.2.4.3.6 ), SetConfigurationDataCmd (see 6.2.4.3.7 ), ReassignControlCmd (see 6.2.4.3.8 ), SetCommunicationConfigurationCmd (see 6.2.4.3.9 ), and EnableCommunicationCmd (see 6.2.4.3.10 ). For a formal definition ... formal definition of the ConnectionEndpointConfigurationDataType, see 10.14 . If CommandMask VerifyFunctionalEntityCmd , CreateConnectionEndpointCmd , EstablishControlCmd , SetConfigurationDataCmd , ReassignControlCmd , SetCommunicationConfigurationCmd , or EnableCommunicationCmd is set, ConnectionEndpointConfigurations shall contain at least one element. If CommandMask VerifyFunctionalEntityCmd , CreateConnectionEndpointCmd
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.2.4.3.1 Overviewindividual commands shall be processed in the order: VerifyAssetCmd , VerifyFunctionalEntityCmd , ReserveCommunicationIdsCmd , CreateConnectionEndpointCmd , EstablishControlCmd , SetConfigurationDataCmd , ReassignControlCmd , SetCommunicationConfigurationCmd , EnableCommunicationCmd, which is illustrated in Figure 20 . A Client may issue the same command ... consecutive EstablishConnections Calls , e.g., to apply large configuration data in multiple Calls with SetConfigurationDataCmd . If the processing of a command results in an error, the processing of the command sequence
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.2.4.3.7 Command SetConfigurationDataCmdCommand SetConfigurationDataCmd If CommandMask SetConfigurationDataCmd is set, the EstablishConnections implementation shall apply the Value to the Key for each element in ConnectionEndpointConfigurations and each element in ConfigurationData . If the ConnectionEndpoint
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.7.3.2 Establishing ConnectionsConnectionManager shall use the following commands in the following sequence: CreateConnectionEndpointCmd , EstablishControlCmd , SetConfigurationDataCmd , ReassignControlCmd , and SetCommunicationConfigurationCmd . The sequence may be built by having one EstablishConnections Call with the required commands ... commands in consecutive EstablishConnections Calls , e.g., to apply large configuration data, multiple Calls with SetConfigurationDataCmd can be required. If AutomationComponentConfiguration CommandBundleRequired is set to TRUE, the ConnectionManager shall issue
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelusing the EstablishControlCmd, set the EngineeringUnits with the desired unit (e.g., °F) using the SetConfigurationDataCmd , and reassign control to the ConnectionEndpoint using ReassignControlCmd . Then as long as the connection
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles5.2.3 UAFX AutomationComponentEstablishConnections Method EstablishControlCmd command. Server UAFX AutomationComponent ConnectionEstablishment SetConfigurationData Supports the EstablishConnections Method SetConfigurationDataCmd command. Server UAFX AutomationComponent ConnectionEstablishment ReassignControl Supports the EstablishConnections Method ReassignControlCmd command. Server UAFX AutomationComponent ConnectionEstablishment
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles5.2.6 UAFX ConnectionManagerEstablishConnections Method. Client UAFX Client ConnectionManager SetConfigurationData Is capable of issuing the SetConfigurationDataCmd command of the EstablishConnections Method. Client UAFX Client ConnectionManager ReassignControl Is capable of issuing the ReassignControlCmd command