Search
6 result(s) for SensorValue
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: BasicsAlarmMonitor ExclusiveLevelAlarmType O 0:HasComponent Variable RawValue Double{Any} AnalogUnitRangeType M 0:HasComponent Variable SensorValue Double{Any} AnalogUnitRangeType M 0:HasComponent Object Calibration 1:FunctionalGroupType O 0:HasComponent Variable CalibrationValues ... Sensor element, such as the Nernst voltage of a pH Sensor element. SensorValue is the calibrated and optionally compensated/filtered process value. Calibration is used to organize parameters for configuration
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: Basicsdefined in 7.5.2 0:HasComponent Variable RawValue Double{OneOrMoreDimensions} AnalogUnitRangeType M 0:HasComponent Variable SensorValue Double{OneOrMoreDimensions} AnalogUnitRangeType M Conformance Units LADS AnalogArraySensorFunctionType RawValue is the raw value measured ... Sensor element, such as the Nernst voltage of a pH Sensor element. SensorValue is the calibrated and optionally compensated/filtered process value
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: BasicsAnalogSensorFunctionType defined in 7.5.2 0:HasComponent Variable RawValue Double AnalogUnitRangeType M 0:HasComponent Variable SensorValue Double AnalogUnitRangeType M Conformance Units LADS AnalogScalarSensorFunctionType RawValue is the raw value measured ... Sensor element, such as the Nernst voltage of a pH Sensor element. SensorValue is the calibrated and optionally compensated/filtered process value
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: BasicsBrowseName DataType TypeDefinition Other Subtype of the BaseSensorFunctionType defined in 7.5.1 0:HasComponent Variable SensorValue BaseDataType DiscreteItemType M 0:HasComponent Object Operational 1:FunctionalGroupType M Conformance Units LADS DiscreteSensorFunctionType SensorValue
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: BasicsBrowseName DataType TypeDefinition Other Subtype of the DiscreteSensorFunctionType defined in 7.5.1 0:HasComponent Variable SensorValue 0:Boolean TwoStateDiscreteType M Conformance Units LADS TwoStateDiscreteSensorFunctionType SensorValue a Boolean sensor value representing
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: BasicsBrowseName DataType TypeDefinition Other Subtype of the DiscreteSensorFunctionType defined in 7.5.1 0:HasComponent Variable SensorValue 0:UInt32 MultiStateDiscreteType M Conformance Units LADS MultiStateDiscreteSensorFunctionType SensorValue a UInt:32 sensore representing