Search
4 result(s) for Reporting
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services5.13.1.3 Monitoring modesampling of a MonitoredItem , and also to provide for independently enabling and disabling the reporting of Notifications . This capability allows a MonitoredItem to be configured to sample, sample and report ... MonitoredItem is enabled (i.e. when the MonitoringMode is changed from DISABLED to SAMPLING or REPORTING ) or it is created in the enabled state, the Server shall report the first sample
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services5.13.1.6 Triggering modelsampling-only so that it will sample and queue Notifications without reporting them. Figure 18 illustrates this concept. Figure 18 - Triggering model The triggering mechanism is a useful feature that ... triggers the items to report. If the monitoring mode of the triggering item is REPORTING, then it is reported when the triggering item triggers the items to report
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services6.6.2.4.5.4 Hotconnects to multiple Servers and establishes Subscription (s) in each where only one is Reporting ; the others are Sampling only. The Client should setup the queue size for the MonitoredItems ... gets Publish Responses from the backup Server . On a Failover the Client shall enable Reporting on the Server with the next highest availability. The Client connects to multiple Servers
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Servicesvalue for each data MonitoredItem in the Subscription where the MonitoringMode is set to Reporting . If a value is queued for a data MonitoredItem , the next value in the queue