Search
6 result(s) for QualifierValue
-
OPC-30142 – OPC UA for PROFINET Remote IOarray element is RioPaAnalogValueDataType which has two members: Value contains the Process Value and QualifierValue contains the status information associated with each value. The SimulationValues array of RioPaAnalogValueDataType structures contains
-
OPC-30142 – OPC UA for PROFINET Remote IOarray element is RioPaDigitalValueDataType which has two members: Value contains the Process Value and QualifierValue contains the status information associated with each value. The SimulationValues array of RioPaDigitalValueDataType structures contains
-
OPC-30142 – OPC UA for PROFINET Remote IOHasComponent Variable DataValue 0:Boolean 0:BaseDataVariableType O, RO 0:HasComponent Variable QualifierValue 0:Byte RioPaProcessValueQualifierVariableType O, RO Conformance Units PNRIO Channel Objects The DataValue Variable contains the Process Value ... transmitted in the telegram signal. The Value of the QualifierValue Variable contains the status information as transmitted in the telegram signal. The optional components of the QualifierValue Variable contain refined
-
OPC-30142 – OPC UA for PROFINET Remote IOHasComponent Variable DataValue 0:Boolean 0:BaseDataVariableType O, RO 0:HasComponent Variable QualifierValue 0:Boolean RioFaProcessValueQualifierVariableType O, RO Conformance Units PNRIO Channel Objects The DataValue Variable contains the Process Value ... transmitted in the telegram signal. The Value of the QualifierValue Variable contains the qualifier bit. The optional Quality component of the QualifierValue Variable contains the status information encoded as RioQualityEnumeration
-
OPC-30142 – OPC UA for PROFINET Remote IOHasComponent Variable DataValue 0:Number 0:BaseAnalogType O, RO 0:HasComponent Variable QualifierValue 0:Byte RioPaProcessValueQualifierVariableType O, RO Conformance Units PNRIO Channel Objects The DataValue Variable contains the analog Process ... case if the Server is running directly on the Device . The Value of the QualifierValue Variable contains the status information as transmitted in the telegram signal. The optional components
-
OPC-30142 – OPC UA for PROFINET Remote IOHasComponent Variable DataValue 0:Number 0:BaseAnalogType O, RO 0:HasComponent Variable QualifierValue 0:Boolean RioFaProcessValueQualifierVariableType O, RO Conformance Units PNRIO Channel Objects The DataValue Variable contains the analog Process ... case if the Server is running directly on the Device . The Value of the QualifierValue Variable contains the qualifier bit. The optional Quality component of the QualifierValue Variable contains