Search
4 result(s) for NonExclusiveLimitAlarmType
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.8.20 NonExclusiveLimitAlarmTypeNonExclusiveLimitAlarmType The NonExclusiveLimitAlarmType is used to specify the common behaviour for Alarm Types with multiple non-exclusive limits. The NonExclusiveLimitAlarmType is illustrated in Figure 21 . Figure 21 - NonExclusiveLimitAlarmType The NonExclusiveLimitAlarmType ... formally defined in Table 97 and Table 98 . Table 97 - NonExclusiveLimitAlarmType definition Attribute Value BrowseName NonExclusiveLimitAlarmType IsAbstract False References NodeClass BrowseName DataType TypeDefinition Modelling Rule Subtype of the LimitAlarmType defined
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.8.21.2 NonExclusiveLevelAlarmTypethen an instance of NonExclusiveLevelAlarmType should be used. The NonExclusiveLevelAlarmType is based on the NonExclusiveLimitAlarmType . It is formally defined in Table 99 . Table 99 - NonExclusiveLevelAlarmType definition Attribute Value BrowseName NonExclusiveLevelAlarmType ... IsAbstract False References NodeClass BrowseName DataType TypeDefinition ModellingRule Subtype of the NonExclusiveLimitAlarmType defined in clause 5.8.20 . ConformanceUnits A & C Non-Exclusive Level No additional Properties to the NonExclusiveLimitAlarmType
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.8.22.2 NonExclusiveDeviationAlarmTypethen an instance of NonExclusiveDeviationAlarmType should be used. The NonExclusiveDeviationAlarmType is based on the NonExclusiveLimitAlarmType . It is formally defined in Table 101 . Table 101 - NonExclusiveDeviationAlarmType definition Attribute Value BrowseName NonExclusiveDeviationAlarmType ... IsAbstract False References NodeClass BrowseName DataType TypeDefinition ModellingRule Subtype of the NonExclusiveLimitAlarmType defined in clause 5.8.20 . HasProperty Variable SetpointNode NodeId PropertyType Mandatory HasProperty Variable BaseSetpointNode NodeId PropertyType Optional ConformanceUnits
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.8.23.2 NonExclusiveRateOfChangeAlarmTypesame time this AlarmConditionType should be used The NonExclusiveRateOfChangeAlarmType is based on the NonExclusiveLimitAlarmType . It is formally defined in Table 103 . Table 103 - NonExclusiveRateOfChangeAlarmType definition Attribute Value BrowseName NonExclusiveRateOfChangeAlarmType IsAbstract ... False References NodeClass BrowseName DataType TypeDefinition ModellingRule Subtype of the NonExclusiveLimitAlarmType defined in clause 5.8.20 . HasProperty Variable EngineeringUnits EUInformation PropertyType Optional ConformanceUnits A & C Non-Exclusive RateOfChange EngineeringUnits provides