OPC-30142 – OPC UA for PROFINET Remote IO7.2.2.1 RioPaAnalogInputChannelTypeHasComponent Variable Mode RioChannelModeEnumeration 0:BaseDataVariableType M, RO 0:HasComponent Variable ManualProcessValue RioAnalogDataType 0:BaseDataVariableType O, RO 0:HasComponent Variable SimulationEnabled 0:Boolean 0:BaseDataVariableType M, RO 0:HasComponent Variable ... operation encoded as RioChannelModeEnumeration . If Mode has the Value MANUAL, the Value of the ManualProcessValue Variable shall be used as Process Value . The ManualProcessValue Variable contains the value used
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.2.3 SetManualProcessValue MethodSetManualProcessValue Method This Method sets the Value of the ManualProcessValue Variable . The security constraints defined in chapter 6.7 apply. Signature SetManualProcessValue ( [in] RioAnalogDataType ManualProcessValue ); Argument Description ManualProcessValue Desired Value ... ManualProcessValue Variable . The Method Result Codes (defined in Call Service) are defined in Table 34 . Table 34 - Possible Method result codes Result Code Description Good The Method execution was successful
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.4.1 RioPaDigitalInputChannelTypeHasComponent Variable Mode RioChannelModeEnumeration 0:BaseDataVariableType M, RO 0:HasComponent Variable ManualProcessValue 0:Boolean 0:BaseDataVariableType O, RO 0:HasComponent Variable SimulationEnabled 0:Boolean 0:BaseDataVariableType M, RO 0:HasComponent ... operation encoded as RioChannelModeEnumeration . If Mode has the Value MANUAL, the Value of the ManualProcessValue Variable shall be used as Process Value . The ManualProcessValue Variable contains the value used
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.4.3 SetManualProcessValue MethodSetManualProcessValue Method This Method sets the Value of the ManualProcessValue Variable . The security constraints defined in chapter 6.7 apply. Signature SetManualProcessValue ( [in] 0:Boolean ManualProcessValue ); Argument Description ManualProcessValue Desired Value ... ManualProcessValue Variable . The Method Result Codes (defined in Call Service) are defined in Table 46 . Table 46 - Possible Method result codes Result Code Description Good The Method execution was successful
-
OPC-30142 – OPC UA for PROFINET Remote IO10.4.4 RioChannelModeEnumerationRioChannelModeEnumeration Items Name Value Description AUTO 0 Do not use the value of the ManualProcessValue variable as Process Value of the RIO Channel . MANUAL 1 Use the value ... ManualProcessValue variable as Process Value of the RIO Channel . OUT_OF_SERVICE 2 The RIO Channel is out of service. Its representation in the AddressSpace is defined in Table