OPC-30020 – MDIS OPC UA Companion SpecificationMDISCIMVObjectType Definition Table 56 defines the structure of an MDISCIMVObjectType . Any vendor specified Properties that have been implemented within a project should be documented within a similar format and supplied ... vendor. The addition of vendor specific properties will result in a subtype of the MDISCIMVObjectType . When an MDISCIMVObjectType Instance is disabled the MDISBaseObjectType defaults are followed - no additional values will
-
OPC-30020 – MDIS OPC UA Companion Specification6.1.14 MDISCIMVObjectTypeMDISCIMVObjectType The MDISCIMVObjectType (see 6.9.3 ) is a base type and can be subtyped or an instance of it can be directly created. The CIMV (Chemical Injection Metering Valve) is used
-
OPC-30020 – MDIS OPC UA Companion Specification6.9.1 IntroductionIntroduction The following section details the generic MDISCIMVObjectType and defines the properties associated with it. This is in general a vendor and operator independent description, but all users ... MDISCIMVObjectType can add vendor specific data. The vendor specific data should be defined as part of a subtype of the MDISCIMVObjectType defined in this document. It is assumed that
-
OPC-30020 – MDIS OPC UA Companion Specification6.9.2 Overviewprovides an overview of the CIMV Object as defined by MDIS and the MDISCIMVObjectType . It includes all items that are defined by the MDISBaseObjectType . Figure 18 - MDISCIMVObjectType Overview
-
OPC-30020 – MDIS OPC UA Companion Specification6.9.5 SetFlowRate Methodhowever the actual units are device specific. Refer to FlowRate and TargetFlowRate component of MDISCIMVObjectType discussed in 6.9.3 . The Method will complete when the command has been accepted. After receiving
-
OPC-30020 – MDIS OPC UA Companion Specification6.9.6 SetPosition MethodTargetPosition and will automatically maintain the position. Refer to Position and TargetPosition component of MDISCIMVObjectType discussed in 6.9.3 . The CIMV must be in operation mode Position_1 (refer
-
OPC-30020 – MDIS OPC UA Companion SpecificationHasComponent Object <MotorPlaceholder> MDISMotorObjectType OP 0:HasComponent Object <CIMVPlaceholder> MDISCIMVObjectType OP 0:HasComponent Object <CounterPlaceholder> MDISCounterObjectType OP HasInterlock Variable <InterlockPlaceholder> InterlockVariableType ... subtype. Each object instance shall have a unique BrowseName and must be of MDISCIMVObjectType or a subtype of it. <CounterPlaceholder> denotes that a subtype of this ObjectType
-
OPC-30020 – MDIS OPC UA Companion Specification9.2 InterlockForNonDefeatableStartInterlock, NonDefeatableStopInterlock, NonDefeatableCommandInProgressInterlock The Variable shall be part of an: MDISValveObjectType MDISChokeObjectType MDISElectricChokeObjectType MDISMotorObjectType MDISCIMVObjectType MDISAggregateObjectType , Or a subtype of one of these types or an instance
-
OPC-30020 – MDIS OPC UA Companion Specification14.2.2 ServerSupports the SetManual Method Server MDIS CIMV NonDefeatableCloseInterlock Supports the optional aspect of the MDISCIMVObjectType related to NonDefeatableCloseInterlock . This includes NonDefeatableCloseInterlock flag and providing at least one InterlockFor reference ... Variable of InterlockVariableType . Server MDIS CIMV NonDefeatableOpenInterlock Supports the optional aspect of the MDISCIMVObjectType related to NonDefeatableOpenInterlock . This includes NonDefeatableOpenInterlock flag and providing at least one InterlockFor reference
-
OPC-30020 – MDIS OPC UA Companion Specification14.2.3 ClientMethod Client MDIS CIMV Client NonDefeatableCloseInterlock Makes use of the optional aspect of the MDISCIMVObjectType related to NonDefeatableCloseInterlock . This includes NonDefeatableCloseInterlock flag and providing at least one InterlockFor reference ... InterlockVariableType . Client MDIS CIMV Client NonDefeatableOpenInterlock Makes use of the optional aspect of the MDISCIMVObjectType related to NonDefeatableOpenInterlock . This includes NonDefeatableOpenInterlock flag and providing at least one InterlockFor reference
-
OPC-30020 – MDIS OPC UA Companion Specification14.3.2.15 MDIS CIMV Model Server Facetthat describes the base characteristics for an OPC UA Server that is exposing the MDISCIMVObjectType . Table 146 - MDIS CIMV Model Server Facet Group Conformance Unit / Profile Title Optional MDIS Base
-
OPC-30020 – MDIS OPC UA Companion Specification14.3.3.15 MDIS CIMV Model Client FacetFacet that describes the base characteristics for an OPC UA Client using the MDISCIMVObjectType model. Table 166 - MDIS CIMV Model Client Facet Group Conformance Unit / Profile Title Optional MDIS Base