OPC-10000-100 – OPC Unified Architecture - Part 100: Devices10.1 Generalrelation of the Indication to a classification ObjectType provide the semantic. The StartValue and LimitValue Properties indicate the range of the Value . Table 143 - Lifetime examples Node CertificateValidity PartsProduced LifetimeVariable ... EngineeringUnits (M) day number of parts StartValue (M) 365 0 WarningValues (O) 10 950 LimitValue (M) 0 1000 Indication (O) TimeIndicationType NumberOfPartsIndicationType For the CertificateValidity example, the instance
-
OPC-10000-100 – OPC Unified Architecture - Part 100: DevicesHasProperty Variable 1:StartValue 0:Number 0:PropertyType M 0:HasProperty Variable 1:LimitValue 0:Number 0:PropertyType M 0:HasProperty Variable 1:Indication 0:NodeId 0:PropertyType ... DataType shall be the same as for the Value of the Variable . The mandatory LimitValue indicates when the end of lifetime has been reached. The engineering unit is the same
-
OPC-40210 – OPC UA for Geometric Measurement Systems8.3 SensorTypehour, days) and the StartValue is the timestamp (Unix timestamp) of the last qualification. LimitValue is the chosen value at which the tool is no longer qualified. WarningValue
-
OPC-40501-1 – OPC UA for Machine Tools - Part 1: Machine Monitoring and Job Management11.1 ToolLifeTypeHasProperty Variable StartValue 0:Number 0:PropertyType O, RO 0:HasProperty Variable LimitValue 0:Number 0:PropertyType O, RO 0:HasProperty Variable Indication ToolLifeIndication 0:PropertyType M, RO 0:HasProperty ... initial value for the tool life measurement (the one a new tool has). LimitValue is the chosen value at which the tool shall be changed. Indication is shows what property