7 result(s) for LADS Device
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: Basics4.1.3.1 Overviewrelationship between various state machines and status variables in the context of a LADS Device, its Components, and Functional Units. The relationship between these state machines and status variables ... crucial for understanding the operation and management of a LADS Device. The state of the LADS Device state machine and the FunctionalUnit state machines come first and form the basis
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: BasicsFunctional Units of this Device . HierarchicalLocation pro vides the hierarchical location of the LADS Device . The structure within the string may expose several levels. How this is exposed, which delimiters ... more details). OperationalLocation pro vides the operational location of the LADS Device . The structure within the string may expose several levels. How this is exposed, which delimiters are used
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: Basics7.6.2.3 StartWithTargetValueStartWithTargetValue The StartWithTargetValue Method starts a Function on the LADS Device with the target value as an argument. The signature of this Method is specified below. Table 91 and Note
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: Basics7.6.5.1 StartWithTargetValueStartWithTargetValue The StartWithTargetValue Method starts a Function on the LADS Device with the target value as an argument. The signature of this Method is specified below. Table 91 and Note
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: Basics7.6.12.1 StartWithTargetValueStartWithTargetValue The StartWithTargetValue Method starts a Function on the LADS Device with the target value as an argument. The signature of this Method is specified below. Table 91 and Note
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: Basics7.6.13.1 StartWithTargetValueStartWithTargetValue The StartWithTargetValue Method starts a Function on the LADS Device with the target value as an argument. The signature of this Method is specified below. Table 91 and Note
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: Basicsunit accurately reflects the operational status of the overall device. The DeviceHealth of the LADS Device should be determined by aggregating the DeviceHealth of its components. The specific rules