Search
11 result(s) for Id
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditionsthis subtype is not shown in the definition of the StateVariableType HasProperty Variable Id Boolean PropertyType Mandatory HasProperty Variable TransitionTime UtcTime PropertyType Optional HasProperty Variable EffectiveTransitionTime UtcTime PropertyType Optional HasProperty ... contain the name "Enabled" when True and "Disabled" when False. Id is inherited from the StateVariableType and overridden to reflect the required DataType (Boolean). The value
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditionsthat have a Boolean DataType . The Variable can be thought of as representing the Id of the ActiveState of an Alarm , i.e. when any of the included Variables have
-
OPC-10000-16 – OPC Unified Architecture - Part 16: State Machines4.4.3 StateVariableTypeBaseDataVariableType defined in OPC 10000-5 HasSubtype VariableType FiniteStateVariableType Defined in 4.4.7 HasProperty Variable Id BaseDataType PropertyType Mandatory HasProperty Variable Name QualifiedName PropertyType Optional HasProperty Variable Number UInt32 PropertyType Optional ... Optional HasProperty Variable VendorCode String PropertyType Optional Conformance Units Base Info State Machine Instance Id is a name which uniquely identifies the current state within the StateMachineType . A subtype
-
OPC-10000-16 – OPC Unified Architecture - Part 16: State Machines4.4.5 TransitionVariableTypeBaseDataVariableType defined in OPC 10000-5 HasSubtype VariableType FiniteTransitionVariableType Defined in 4.4.8 HasProperty Variable Id BaseDataType PropertyType Mandatory HasProperty Variable Name QualifiedName PropertyType Optional HasProperty Variable Number UInt32 PropertyType Optional ... Optional HasProperty Variable EffectiveTransitionTime UtcTime PropertyType Optional Conformance Units Base Info State Machine Instance Id is a name which uniquely identifies a Transition within the StateMachineType . A subtype may restrict
-
OPC-10000-16 – OPC Unified Architecture - Part 16: State Machines4.4.7 FiniteStateVariableTypeClass BrowseName DataType TypeDefinition Modelling Rule Subtype of the StateVariableType defined 4.4.3 HasProperty Variable Id NodeId PropertyType Mandatory Conformance Units Base Info Finite State Machine Instance Id is inherited from
-
OPC-10000-16 – OPC Unified Architecture - Part 16: State MachinesBrowseName DataType TypeDefinition Modelling Rule Subtype of the TransitionVariableType defined in 4.4.5 HasProperty Variable Id NodeId PropertyType Mandatory Conformance Units Base Info Finite State Machine Instance Id is inherited from
-
OPC-10000-16 – OPC Unified Architecture - Part 16: State Machines4.4.18 AuditUpdateStateEventTypename of the Method prefixed with "Method/". OldStateId reflects the Id of the state prior the change. NewStateId reflects the new Id of the state after the change
-
OPC-10000-22 – OPC Unified Architecture - Part 22: Base Network Model5.2.6 ISrClassType InterfaceTypeDefinition Modelling Rule Subtype of the BaseInterfaceType defined in OPC 10000-5 HasComponent Variable Id Byte BaseDataVariableType Mandatory HasComponent Variable Priority Byte BaseDataVariableType Mandatory HasComponent Variable Vid UInt16 BaseDataVariableType Mandatory ... Conformance Units BNM TSN Base Info Id is a Byte and specifies the SRclassID in a numeric representation of the SR classes which is supported by a particular Bridge Port
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelSubtype of the 0:BaseObjectType defined in OPC 10000-5 0:HasProperty Variable 3:Id 0:UInt16 0:PropertyType O 0:HasProperty Variable 3:Name 0:String 0:PropertyType ... Slot Base UAFX AssetConnector Socket Base UAFX AssetConnector Clamp Base UAFX AssetConnector ClampBlock Base Id provides the (physical) ID of the connector, representing the physical location of the connector
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.3.5 SlotType definitionClass BrowseName DataType TypeDefinition Other Subtype of the 3:AssetConnectorType 0:HasProperty Variable 3:Id 0:UInt16 0:PropertyType M 0:HasProperty Variable 3:LogicalId 0:UInt16 0:PropertyType ... ConformanceUnits UAFX AssetConnector Slot Base Id is from AssetConnectorType and is mandatory in SlotType . It shall start at 1 and increment by 1 for each physical slot in a rack
-
OPC-10000-100 – OPC Unified Architecture - Part 100: Devices8.7.5 Solution packagesAssetConnectorTypes . AssetConnectorType 0:NodeId Connector type as defined in OPC 10000-81 . Additionally either Id or Name shall be specified. False ConnectorId 0:UInt16 Id of the connector. True ConnectorName ... following the AssetConnectors (see OPC 10000-81 ) identified by its type and either its Id or its Name . If AssetsTypes of OPC 10000-81 are used, TargetScope can be used