Search
5 result(s) for DeviceId
-
OPC-30120 – OPC UA for IO-Link Devices and IO-Link Masters - IO-Link: OPC Unified Architecture7.1.2 OverviewHasProperty Variable RevisionID String PropertyType Mandatory HasProperty Variable VendorID UInt16 PropertyType Mandatory HasProperty Variable DeviceID UInt32 PropertyType Mandatory HasProperty Variable DeviceAccessLocks UInt16 PropertyType Optional HasProperty Variable ProfileCharacteristic UInt16[] PropertyType Optional ... ModellingRule to Mandatory. Table 9 - References of Identification Object References BrowseName Comment Organizes DeviceID Variable defined in Table 8 . Organizes VendorID Variable defined in Table 8 . Organizes 2:SerialNumber Variable
-
OPC-30120 – OPC UA for IO-Link Devices and IO-Link Masters - IO-Link: OPC Unified Architecture7.5.2 OverviewFunctionalGroupType Mandatory HasComponent Object Management FunctionalGroupType Mandatory HasComponent Object Statistics FunctionalGroupType Mandatory HasProperty Variable DeviceID UInt32 PropertyType Mandatory HasProperty Variable ProductID String PropertyType Optional HasProperty Variable ProductText String PropertyType Optional ... ModellingRule to Mandatory. Table 24 - References of Identification Object References BrowseName Comment Organizes DeviceID Variable defined in Table 23 . Organizes VendorID Variable defined in Table 23 . Organizes ApplicationSpecificTag Variable defined
-
OPC-30120 – OPC UA for IO-Link Devices and IO-Link Masters - IO-Link: OPC Unified Architecturereferenced by the ConfiguredDevice Object, which is part of the Configuration Object HasComponent Variable DeviceID UInt32 BaseDataVariableType Mandatory HasComponent Variable VendorID UInt16 BaseDataVariableType Mandatory The following Parameters are also referenced ... selection process are defined in section 6.1.7 . The mandatory, read-only Variable DeviceID shall be mapped to DeviceID of the PortConfigList structure defined in the SMI (see IO-Link Addendum
-
OPC-30140 – OPC UA for PROFINET6.3.1.7.1 IPnInterfaceTypeHasProperty Variable DeviceVendor String PropertyType Optional HasProperty Variable VendorId UInt16 PropertyType Mandatory HasProperty Variable DeviceId UInt16 PropertyType Mandatory HasProperty Variable DeviceInstance UInt16 PropertyType Optional HasProperty Variable OEMVendorId UInt16 PropertyType Optional ... DeviceRoleDetails DeviceVendor DCP DCP-Identify-ResPDU | DeviceVendorValue VendorId DCP DCP-Identify-ResPDU | DeviceIDBlockRes | DeviceIDValue DeviceId DCP DCP-Identify-ResPDU | DeviceIDBlockRes | DeviceIDValue DeviceInstance DCP DCP-Identify-ResPDU | DeviceInstanceValue OEMVendorId
-
OPC-30140 – OPC UA for PROFINET6.3.1.8.2 PnAssetTypeHasProperty Variable Organization UInt16 PropertyType Mandatory HasProperty Variable VendorId UInt16 PropertyType Mandatory HasProperty Variable DeviceId UInt16 PropertyType Mandatory HasProperty Variable DeviceSubId UInt16 PropertyType Mandatory GeneratesEvent ObjectType PnAssetChangedEventType The BrowseName ... Number TypeIdentification Read AssetManagementData | AM_TypeIdentification Organization Read AssetManagementData | AM_DeviceIdentification.Organization VendorId Read AssetManagementData | AM_DeviceIdentification.VendorID DeviceId Read AssetManagementData | AM_DeviceIdentification.DeviceID DeviceSubId Read AssetManagementData | AM_DeviceIdentification.DeviceSubID If the AM_Location field is coded using