Search
9 result(s) for ConditionSubClassId
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model6.4.2 BaseEventTypeHasProperty Variable ConditionClassId NodeId PropertyType Optional HasProperty Variable ConditionClassName LocalizedText PropertyType Optional HasProperty Variable ConditionSubClassId NodeId[] PropertyType Optional HasProperty Variable ConditionSubClassName LocalizedText[] PropertyType Optional Conformance Units Address Space Events EventId ... class. ConditionClassName provides the DisplayName of the of the ConditionClassType provided in the ConditionClassId . ConditionSubClassId specifies additional class[es] that apply to the Event. It is the NodeId
-
OPC-10000-26 – Part 26: LogObject - Part 26: LogObject Model5.1 Overviewalso contain LogRecords that result from Events that have a ConditionClassId or ConditionSubClassId of LogEntryConditionClassType that are reported by the Object on which the LogObject instance is declared
-
OPC-10000-26 – Part 26: LogObject - Part 26: LogObject Model6.1 ConceptsEvents that would be available from the Area2 Object that have a ConditionClassId or ConditionSubClassId of LogEntryConditionClass . In addition the LogObject could store additional fields from Events in the AdditionalData
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelObject . If AutomationComponentLog is supported, this AuditEvent shall set either the ConditionClassId or a ConditionSubClassId to LogEntryConditionClassType , which results in the Audit Event being mapped to LogObject records. The mapping
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelConnection ). If AutomationComponentLog is supported, this AuditEvent shall set either the ConditionClassId or a ConditionSubClassId to LogEntryConditionClassType , which results in the AuditEvent being mapped to LogObject records. The RemovedEndpoint
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelConnectionManagerLog or AutomationComponentLog is supported, this AuditEvent shall set either the ConditionClassId or a ConditionSubClassId to LogEntryConditionClassType , which results in the AuditEvent being mapped to LogObject records. The StatusCodeId shall
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelConnectionConfigurationSet . If ConnectionManagerLog is supported, this AuditEvent shall set either the ConditionClassId or a ConditionSubClassId to LogEntryConditionClassType , which results in the AuditEvent being mapped to LogObject records. This applies
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelLogRecord. If ConnectionManagerLog is supported, this Event shall set either the ConditionClassId or a ConditionSubClassId to LogEntryConditionClassType , which results in the Event being mapped to LogObject records. If the LogObject
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelactivity. If ConnectionManagerLog is supported, this Event shall set either the ConditionClassId or a ConditionSubClassId to LogEntryConditionClassType , which results in the Event being mapped to LogObject records. If the LogObject