OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems3.2.3 ComponentComponent CASPart that serves a particular purpose in compressed air generation, treatment, measurement, or storage. Note 1 to entry: Components defined in this specification are: Charging System, Compressor, Condensate Drain
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems3.2.7 DeviceClassDeviceClass Specific class of a CASPart and value of the DeviceClass Property of an instance of the FunctionalGroup Identification of a CASPart . Note 1 to entry: Available DeviceClasses for CASPart
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems3.2.12 Main Control SystemMain Control System CASPart that controls all Components and Airnets simultaneously, represents the Compressed Air System , and serves for communication between the Components and higher-level systems
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems3.2.14 QuantityVariable representing physical measurements performed by a sensor, or calculations performed by a CASPart or the Main Control System to simulate a physical measurement. Note 1 to entry: A physical ... quantity may be measured by an external sensor but is assigned to a specific CASPart . Note 2 to entry: The measuring sensor may be integrated into the CASPart . Note
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems6.4 Identificationmandatory specific value and its ModellingRule changed to mandatory. Table 9 shows for each CASPart what value shall be set for different applications like the DeviceClass , BrowseName and GroupName . Table ... DeviceClass, BrowseName and GroupName for CASParts CASPart Name DeviceClass BrowseName GroupName Airnet - Airnet Airnets Charging System Charging system ChargingSystem ChargingSystems Compressor Compressor Compressor Compressors Condensate Drain Condensate drain CondensateDrain CondensateDrains
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systemsdefined. If a manufacturer or system integrator adds additional alarms or conditions to a CASPart , <Event> shall be used. When instantiating <Event>, a concrete subtypes ... comply with Annex B of OPC 10000-9 - Part 9: Alarms and Conditions, a CASPart must have a HasCondition reference for each instantiated condition using the condition instance as TargetNode
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control SystemsConfigurationType provides a framework for Nodes aimed at configuring the behavior of a CASPart . This specification defines configuration properties for Airnets and the Main Control System . There are no configuration
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systemsabstract DataType 0:Enumeration for HealthState, IntegratedState, and OperatingState shall be changed to a CASPart specific concrete DataType or one of the general DataTypes HealthStateEnum, IntegratedStateEnum, OperatingStateEnum. The InstanceDeclarations