8 result(s) for Bad_InvalidArgument
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Access6.5.4.2 Read processed functionalitycoming first. If startTime and endTime are the same then the Server shall return Bad_InvalidArgument as there is no meaningful way to interpret such a case. If the ProcessingInterval ... match the array of NodesToRead then the Server shall return a StatusCode of Bad_AggregateListMismatch. The aggregateConfiguration parameter allows a Client to override the Aggregate configuration settings supplied
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Accessperformed. The Delete enumeration value is not allow and will result in a Bad_InvalidArgument error. filter EventFilter If the history of Notification conforms to the EventFilter , the history
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Access6.9.4.2 Insert event functionalityerrors occur while processing individual fields then the related o perationResults entry shall indicate Bad_InvalidArgument and the invalid fields shall be indicated in the DiagnosticInformation related to the operationResults ... then the corresponding entry in the operationResults array for the affected Event shall be Bad _ InvalidArgument
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Access6.9.4.3 Replace event functionalitywhile processing individual fields then the operationResults entry for the affected Event shall indicate Bad_InvalidArgument and the invalid fields shall be indicated in the DiagnosticInformation related to the operationResults
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services7.8.2.7 RemoveCertificateMethod allows a Client to remove a single Certificate from the TrustList . It returns Bad_InvalidArgument if the Thumbprint does not match a Certificate in the TrustList . If the Certificate ... Result Code Description Bad_UserAccessDenied The current user does not have the rights required. Bad_InvalidArgument The certificate to remove was not found. Bad_InvalidState The Open Method was called
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services7.9.5 FinishRequestexperiences a network failure while waiting for a completed request it may receive a Bad_InvalidArgument error when it calls the Method again. Recovering from this error is done ... Result Code Description Bad_NotFound The ApplicationId does not refer to a registered application. Bad_InvalidArgument The RequestId is does not reference to a valid request for the application. Bad
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.2.4.3.1 Overviewbundle; the remaining commands are optional. An AutomationComponent requiring bundled commands shall return Bad_InvalidArgument for any command in the set of bundled commands that is issued individually
-
OPC-40010-1 – OPC UA for Robotics - Part 1: Vertical Integration7.16.8 Stop Methodthose listed in the PossibleStopModes Variable (see Section). If not, then a Bad_InvalidArgument Result Code is returned. The possible Method result codes are formally defined in the table below ... Codes (defined in Call Service) Result Code Description Good The task control operation succeeded Bad_InternalError The task control operation failed because of an internal error Bad_ResourceUnavailable The Method