Search
3 result(s) for AcknowledgeAlarms
-
OPC-30060 – OPC UA for Tobacco Machine Communication8.4.2 AcknowledgeAlarms MethodAcknowledgeAlarms Method The AcknowledgeAlarms Method acknowledges all alarms of the machine module. The acknowledgement is cascades to other objects belonging to the machine module e.g., equipment modules and control modules ... signature of this Method is specified below. Table 24 specifies the Arguments representation. Signature AcknowledgeAlarms ( [out] MethodExecutionFeedbackType ExecutionFeedback); Table 24 - AcknowledgeAlarms Method Arguments Argument Description ExecutionFeedback The extended feedback returning
-
OPC-30060 – OPC UA for Tobacco Machine Communication8.17.2 AcknowledgeAlarms MethodAcknowledgeAlarms Method The AcknowledgeAlarms method acknowledges the alarms of the equipment module and control modules belonging to it. The signature of this Method is specified below. Table 69 specifies ... Arguments representation. Signature AcknowledgeAlarms ( [out] MethodExecutionFeedbackType ExecutionFeedback); Table 69 - AcknowledgeAlarms Method Arguments Argument Description ExecutionFeedback The extended feedback returning a detailed message in case of execution failure
-
OPC-30060 – OPC UA for Tobacco Machine Communication8.22.2 AcknowledgeAlarms MethodAcknowledgeAlarms Method The AcknowledgeAlarms Method acknowledges the alarms of the control module. The signature of this Method is specified below. Table 79 specifies the Arguments representation. Signature AcknowledgeAlarms ( [out] MethodExecutionFeedbackType ... ExecutionFeedback); Table 79 - AcknowledgeAlarms Method Arguments Argument Description ExecutionFeedback The extended feedback returning a detailed message in case of execution failure