6 result(s) for 0:KeyValuePair
-
OPC-30143 – OPC UA for PROFINET Encoder - Part <mm>: <Part Name>7.6.1 SetAxisConfig Methodalso have locked the parent EncoderChannelType Object before invoking the Method . Signature SetAxisConfig ( [in] 0:KeyValuePair[] AxisConfigParameters, [out] 0:KeyValuePair[] AxisConfigParametersResult ); Argument Description AxisConfigParameters Array of 0:KeyValuePair structures containing ... this component and must have the same DataType . AxisConfigParametersResult Array of 0:KeyValuePair structures. The array shall be empty if successful. The array shall contain one element for each failed
-
OPC-30143 – OPC UA for PROFINET Encoder - Part <mm>: <Part Name>7.7.1 SetControlConfig Methodalso have locked the parent EncoderChannelType Object before invoking the Method . Signature SetControlConfig ( [in] 0:KeyValuePair[] ControlConfigParameters, [out] 0:KeyValuePair[] ControlConfigParametersResult ); Argument Description ControlConfigParameters Array of 0:KeyValuePair structures containing ... this component and must have the same DataType . ControlConfigParametersResult Array of 0:KeyValuePair structures. The array shall be empty if successful. The array shall contain one element for each failed
-
OPC-30143 – OPC UA for PROFINET Encoder - Part <mm>: <Part Name>7.8.1 SetSensorConfig Methodalso have locked the parent EncoderChannelType Object before invoking the Method . Signature SetSensorConfig ( [in] 0:KeyValuePair[] SensorConfigParameters, [out] 0:KeyValuePair[] SensorConfigParametersResult ); Argument Description SensorConfigParameters Array of 0:KeyValuePair structures containing ... this Property and must have the same DataType . SensorConfigParametersResult Array of 0:KeyValuePair structures. The array shall be empty if successful. The array shall contain one element for each failed
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: Basics8.1 KeyValueTypeKeyValueType A key-value pair similar to 0:KeyValuePair which uses 0: String instead of 0: QualifiedName . The structure is defined in Table 127 . Table 127 - KeyValueType Structure Name Type
-
OPC-40444 – OPC UA for Textile Testing Devicesadded to a job. For this use case an one-dimensional array of 0:KeyValuePair can be included in the 7:JobOrderParameters of the 7: JobOrderDataType. This 0:KeyValuePair
-
OPC-40450-1 – OPC UA for Joining Systems - Part 1: Base10.22 KeyValueDataTypeKeyValueDataType This structure is similar to 0:KeyValuePair which uses 0:TrimmedString instead of 0:QualifiedName. The structure is defined in Table 248 . Table 250 - KeyValueDataType Structure Name Type Description