Search
9 result(s) for 0:BaseDataVariableType
-
OPC-10000-100 – OPC Unified Architecture - Part 100: Devices4.4.3 UIElement TypeIsAbstract True DataType 0:BaseDataType References NodeClass BrowseName DataType TypeDefinition Other Subtype of the 0:BaseDataVariableType defined in OPC 10000-5 . Conformance Units DI Information Model The Value attribute
-
OPC-30142 – OPC UA for PROFINET Remote IOScalar) DataType RioBitFieldDataType References Node Class BrowseName DataType TypeDefinition Other Subtype of the 0:BaseDataVariableType defined in OPC 10000-5 . 0:HasProperty Variable Offset 0:UInt16 0:PropertyType
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic Model6.7 Data Objectsdefault VariableType for representing parameters obtained using Base Mode Parameter Access shall be 0:BaseDataVariableType . The Base Mode Parameter (BMP) data record is specified using a "RecordMeta" child
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic ModelEnumValueType structure as specified in Table 20 . The representing Variable shall have the TypeDefinition 0:BaseDataVariableType and the Value shall have the 0:Enumeration DataType created as described above ... elements of the assigned text array shall be used as BrowseNames of the 0:BaseDataVariableType Variables representing the array elements. There shall be as many Variables as are needed
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic Model7.1.1 SetApplicationTag MethodData Object modelled as Variable as described in 6.7 . There shall be as many 0:BaseDataVariableType Variables as are needed to represent the Data Objects which shall be represented ... Range 0:PropertyType O, RO <ArrayFolder> 0:HasComponent Variable Element 0:BaseDataType 0:BaseDataVariableType MP, RO <OptionSetVariable> 0:HasProperty Variable BitMask 0:Boolean[] 0:PropertyType
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic ModelGsdGenIoDataItemVariableType The GsdGenIoDataItemVariableType is a subtype of the 0:BaseDataVariableType and represents the GSDML "DataItem" element. It is formally defined in Table 27 . Table 27 - GsdGenIoDataItemVariableType definition Attribute ... Scalar) DataType 0:BaseDataType References NodeClass BrowseName DataType TypeDefinition Other Subtype of the 0:BaseDataVariableType defined in [ OPC 10000-5 ]. 0:HasProperty Variable UseAsBits 0:Boolean 0:PropertyType
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic ModelGsdGenIoBitDataItemVariableType The GsdGenIoBitDataItemVariableType is a subtype of the 0:BaseDataVariableType and represents the GSDML "BitDataItem" element. It is formally defined in Table 28 . Table 28 - GsdGenIoBitDataItemVariableType definition Attribute ... Scalar) DataType 0:Byte References NodeClass BrowseName DataType TypeDefinition Other Subtype of the 0:BaseDataVariableType defined in [ OPC 10000-5 ]. Conformance Units PNGSDGM IO Data The Server shall
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic ModelGsdGenParameterVariableType The GsdGenParameterVariableType is a subtype of the 0:BaseDataVariableType and represents the GSDML "Ref" element (see 6.5 .). It is formally defined in Table 29 . Table 29 - GsdGenParameterVariableType ... Scalar) DataType 0:BaseDataType References NodeClass BrowseName DataType TypeDefinition Other Subtype of the 0:BaseDataVariableType defined in [ OPC 10000-5 ]. 0:HasProperty Variable DefaultValue 0:BaseDataType 0:PropertyType
-
OPC-40501-1 – OPC UA for Machine Tools - Part 1: Machine Monitoring and Job Management11.1 ToolLifeTypeFalse ValueRank -1 DataType Number References NodeClass BrowseName DataType TypeDefinition Other Subtype of the 0:BaseDataVariableType defined in OPC 10000-5 0:HasProperty Variable 0:EngineeringUnits 0:EUInformation 0:PropertyType