This structure contains information needed for the crimping process. The structure is defined in Table 54.

Table 54 – CrimpInputDataType Structure (with field that allows subtypes)

Name

Type

Description

AllowSubtypes

CrimpInputDataType

structure

Subtype of ProcessInputDataType defined in this specification.

ReferencedElement 

7:WireMountingIdDataType

References the product element for which this process is defined.

False

VerifyCrimpHeight

0:Boolean[1]

If set, the NominalCrimpHeight must be measured and returned during the verify and learn process, and the ActualCrimpHeight will be sent back.

False

VerifyCrimpWidth

0:Boolean[1]

If set, the NominalCrimpWidth must be measured and returned during the verify and learn process, and the ActualCrimpWidth will be sent back.

False

VerifyInsulationCrimpHeight

0:Boolean[1]

If set, the NominalInsulationCrimpHeight must be measured and returned during the verify and learn process, and the ActualInsulationCrimpHeight will be sent back.

False

VerifyInsulationCrimpWidth

0:Boolean[1]

If set, the NominalInsulationCrimpWidth must be measured and returned during the verify and learn process, and the ActualInsulationCrimpWidth will be sent back.

False

VerifyPullOutForce

0:Boolean[1]

If set, the PullOutForce must be measured and will be sent back.

False

CrimpForceMonitoring

0:Boolean[1]

If set, the CrimpForce is monitored.

False

Its representation in the AddressSpace is defined in Table 55.

Table 55 – CrimpInputDataType definition

Attribute

Value

BrowseName

CrimpInputDataType

IsAbstract

False

References

NodeClass

BrowseName

DataType

TypeDefinition

Other

Subtype of the ProcessInputDataType defined in this specification.

Conformance Units

WireHarness CrimpInputDataType