The Connection configuration for an autonomous subscriber contains the following configuration information (see Figure E.15):
- EndpointA, indicating InputVariables,
- Flow1 and SubA describing the configuration for the information flow from an unknown Publisher to EndpointA.
For an autonomous subscriber, no ToOutboundFlow Reference is required. Configuration, which applies only to the Publisher of the information flow, can be omitted, i.e., Address and TransmitQos (see E.4.1).