The Method ResetProductionTotals simultaneously resets the totals of the machine components belonging to the following machine folders: DefectDetectionSensors, MaterialLoadingPoints, MaterialOutputPoints, MaterialRejectionPoints.
The master totals belonging to the same objects are not reset.
The signature of this Method is specified below. Table 37 specifies the Arguments representation.
Signature
ResetProductionTotals (
[out] MethodExecutionFeedbackType ExecutionFeedback);
Table 37 – ResetProductionTotals Method Arguments
Argument |
Description |
ExecutionFeedback |
The extended feedback returning a detailed message in case of execution failure. |