The AcknowledgeAlarms Method acknowledges all alarms of the machine module. The acknowledgement is cascades to other objects belonging to the machine module e.g., equipment modules and control modules.

The signature of this Method is specified below. Table 24 specifies the Arguments representation.

Signature

AcknowledgeAlarms (

[out] MethodExecutionFeedbackType ExecutionFeedback);

Table 24 – AcknowledgeAlarms Method Arguments

Argument

Description

ExecutionFeedback

The extended feedback returning a detailed message in case of execution failure.