The CirculationSystemType provides a representation of a single circuit of the cooling system of a plasma surface treatment machine. An Instance of the PlantCoolingSystemType can have several Instances of the CirculationSystemsType as components. The CirculationSystemType is formally defined in Table 46.
Table 46 – CirculationSystemType Definition
| 
 Attribute  | 
        
 Value  | 
||||
| 
 BrowseName  | 
        
 CirculationSystemType  | 
||||
| 
 IsAbstract  | 
        
 False  | 
||||
| 
 References  | 
        
 Node Class  | 
        
 BrowseName  | 
        
 DataType  | 
        
 TypeDefinition  | 
        
 Other  | 
| 
 Subtype of the BaseObjectType defined in OPC 10000-5  | 
|||||
| 
 0:HasComponent  | 
        
 Variable  | 
        
 CoolingCircuitTemperatureOutlet  | 
        
 0:Double  | 
        
 0:AnalogUnitType  | 
        
 O, RO  | 
| 
 0:HasComponent  | 
        
 Variable  | 
        
 CoolingCircuitFlowRate  | 
        
 0:Double  | 
        
 0:AnalogUnitType  | 
        
 O, RO  | 
CoolingCircuitTemperatureOutlet is representing the temperature of the coolant at the outlet of the specific cooling circuit.
CoolingCircuitFlowRate is representing the volume flow of coolant through the specific cooling circuit.