This chapter defines the corresponding Conformance Units for the OPC UA Information Model for Surface Technology General Types.

Table 30 – Conformance Units for OPC UA for Surface Technology General Types

Category

Title

Description

Server

STBaseController Basic

There is at least one instance of the STBaseControllerType on the OPC UA server with the optional Nodes StartUp and ShutDown implemented.

Server

STBaseController MachineryItemState

There is at least one instance of the STBaseControllerType on the OPC UA server with the optional Node MachineryItemState implemented.

Server

STBaseController MachineryOperationMode

There is at least one instance of the STBaseControllerType on the OPC UA server with the optional Node MachineryOperationMode implemented.

Server

STJobManagement Alias

There is at least one instance of the STJobManagementType on the OPC UA server. The three optional Nodes STJobManagementAliases, AddAlias and RemoveAlias are implemented.

Table 31 lists all Profiles defined in this document and defines their URIs.

Table 31 – Profile URIs for Surface Technology General Types

Profile

URI

STBaseController Advanced

http://opcfoundation.org/UA-Profile/SurfaceTechnology/GeneralTypes/Server/STBaseControllerAdvanced

The following sections specify the Facets available for Servers that implement the Surface Technology General Types companion specification. Each section defines and describes a Facet or Profile.

Table 32 defines a Profile that defines advanced support of the STBaseControllerType. All it’s optional nodes defined in this companion specification are implemented.

Table 32 – STBaseControllerAdvanced Server Profile

Group

Conformance Unit / Profile Title

Mandatory / Optional

SurfaceTechnology/GeneralTypes

STBaseController Basic

M

SurfaceTechnology/GeneralTypes

STBaseController MachineryItemState

M

SurfaceTechnology/GeneralTypes

STBaseController MachineryOperationMode

M

This specification does not define any Client Facets.