4.3.3 Data types and lengths transformation between Sercos and OPC UA

In order to access data of Sercos devices via OPC UA, data types and lengths are transformed between Sercos and OPC UA. Table 3 shows the data types and data lengths transformation rules between Sercos and OPC UA.

Table 3 – Transformation rules between Sercos and OPC UA

Sercos

OPC UA

Data Type

Data Length

Data Type

Extended Character Set

1 Octet List

String

Floating-Point number

4 Octet

Float

8 Octet

Double

Integer

2 Octet

Int16

4 Octet

Int32

8 Octet

Int64

Unsigned Integer

or

Binary Number

1 Octet

Byte

2 Octet

UInt16

4 Octet

UInt32

8 Octet

UInt64

Sercos Time

8 Octet

UtcTime

The Sercos list data types are transformed analogue to the single data types, e.g. S-0-0017 (Data type: Integer, Data length: 4 Octed list) is transformed to an array of Int32.