This is a subtype of the Byte DataType with the OptionSetValues Property defined. The OutFlagsType is formally defined in Table 16.
Table 16 – OutFlagsType Values
Value |
Bit No. |
Description |
0 |
Operator acknowledgment at the provider, hereby forwarded to the SafetyConsumer, see OperatorAckProvider in the SAPI of the SafetyProvider, Subclause 6.3.3.2. |
|
1 |
Activation of fail-safe values by the safety application at the SafetyProvider, hereby forwarded to the SafetyConsumer, see ActivateFSV in the SAPI of the SafetyProvider, Subclause 6.3.3.2 |
|
2 |
Enabling and disabling of test mode in the SafetyProvider, hereby forwarded to the SafetyConsumer, see EnableTestMode in the SAPI of the SafetyProvider, Subclause 6.3.3.2 |
Bits 3..7 are reserved for future use shall be set to zero by the SafetyProvider and shall not be evaluated by the SafetyConsumer.
The OutFlagsType representation in the AddressSpace is defined in Table 17.
Table 17 – OutFlagsType Definition
Attribute |
Value |
|||||
BrowseName |
OutFlagsType |
|||||
IsAbstract |
False |
|||||
References |
NodeClass |
BrowseName |
DataType |
TypeDefinition |
Other |
|
Subtype of the Byte DataType defined in OPC 10000-5 |
||||||
0:HasProperty |
Variable |
0:OptionSetValues |
0:LocalizedText [] |
0:PropertyType |
|
|
Conformance Units |
||||||
SafetySupport |