This chapter defines the corresponding Conformance Units for the OPC UA Information Model for Pumps and Vacuum Pumps.

Table 152 – Conformance Units for OPC UA for Pumps and Vacuum Pumps

Category

Title

Description

Server

Base System

The PumpType is implemented by the server.

Server

Historizing

The Historizing Attribute and the HistoryRead Attribute is True for at least one Quantity.

Server

Limit Alarm Status

The ObjectTypes MeasurementsType, DriveMeasurementsType, InletConnectionMeasurementsType and OutletConnectionMeasurementsType have a 0:GeneratesEvent reference targeting one of the subtypes of the 0:LimitAlarmType.

Server

PumpClass Data

The PumpClass Property of the Design FunctionalGroup is instantiated for all instantiated Pumps and carries a legal value.

Server

Pump Connection Port

At least one of the InletConnectionPortType or the OutletConnectionPortType is implemented by the Server.

Server

Pump Control

At least one of ControlType, ActuationType or one of subtypes of ActuationType is implemented by the Server.

Server

Pump Drive Port

The DrivePortType is implemented by the server.

Server

Pump Identification

Supports the PumpIdentificationType with all its mandatory

InstanceDeclarations, and optionally the optional InstanceDeclarations with read access.

Server

PumpPumpType Mandatory Nodes

All nodes declared as mandatory in the PumpType are available in the AdressSpace.

Server

Supervision Health Status