The PtSoftStarterAttributesType provides the common asset attributes of a soft-starter and is formally defined in Table 121. Additional attributes can be found in IEC CDD 62683DB.
Table 121 – PtSoftStarterAttributesType Definition
|
Attribute |
Value |
||||
|
BrowseName |
PtSoftStarterAttributesType |
||||
|
IsAbstract |
False |
||||
|
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
|
Subtype of the PtAssetAttributesType defined in chapter 7.7 |
|||||
|
0:HasProperty |
Variable |
IntegratedByPassSupported |
0:Boolean |
0:PropertyType |
M, RO |
|
0:HasProperty |
Variable |
OperationalCurrent40CRated |
0:Float |
0:PropertyType |
M, RO |
|
0:HasProperty |
Variable |
OperationalVoltageRangeRated |
0:Range |
0:PropertyType |
M, RO |
|
0:HasProperty |
Variable |
MotorOverloadProtectionIntegrated |
0:Boolean |
0:PropertyType |
M, RO |
|
Conformance Units |
|||||
|
Powertrain Attributes Information |
|||||
PtSoftStarterAttributesType properties are descripted in IEC Common Data Dictionary (CDD).
The properties of the PtMotorStarterAttributesType have additional references which are defined in Table 122.
Table 122 – PtSoftStarterAttributesType Additional References
|
SourceBrowsePath |
Reference Type |
Is Forward |
TargetBrowsePath |
|
IntegratedByPassSupported
|
0:HasDictionaryEntry |
0:True |
|
|
OperationalCurrent40CRated
|
0:HasDictionaryEntry |
0:True |
|
|
OperationalVoltageRangeRated
|
0:HasDictionaryEntry |
0:True |
|
|
MotorOverloadProtectionIntegrated
|
0:HasDictionaryEntry |
0:True |
|