The PtOutputConverterAttributesType describes an information model for the output converter of a drive. This element changes direct electric current to single-phase or polyphase alternating current for controlling a motor or for another frequency converting reason (e.g. for usage in another power supply) and is formally defined in Table 103.
Table 103 – PtOutputConverterAttributesType Definition
Attribute |
Value |
||||
BrowseName |
PtOutputConverterAttributesType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the PtAssetAttributesType defined in chapter 7.7 |
|||||
0:HasComponent |
Variable |
<PwmSwitchingFrequency> |
0:Float |
0:AnalogUnitType |
MP, RO |
0:HasComponent |
Variable |
EfficiencyClass |
0:UInt16 |
0:MultiStateValueDiscreteType |
O, RO |
Conformance Units |
Powertrain Attributes Information |
<PwmSwitchingFrequency> is the switching (between on and off) frequency of the load (power, current, voltage) sent to the motor, by using a Power Width Modulation mechanism. The unit shall be hertz [Hz].
EfficiencyClass contains a description of the input converter efficiency after elimination of the losses. The values of the MultiStateValueDiscreteType variable are defined in Table 104 and shall be used. The values 0-199 are reserved for future extensions of this specification. The values 200-299 shall be used for vendor-specific extensions of this variable.
Table 104 – PtOutputConverterAttributesType Attribute values for child Nodes
BrowsePath |
Value Attribute |
Description Attribute |
||
|
[ { "Value": 0, "DisplayName": "IE1", "Description": "Standard Efficiency" }, { "Value": 1, "DisplayName": "IE2", "Description": "High Efficiency" }, { "Value": 2, "DisplayName": "IE3", "Description": "Premium Efficiency" }, { "Value": 3, "DisplayName": "IE4", "Description": "Super Premium Efficiency" }, { "Value": 4, "DisplayName": "IE5", "Description": "Ultra Premium Efficiency" }, { "Value": 5, "DisplayName": "IES0", "Description": "Relative losses are higher than 20 % of the value defined by the RPDS" }, { "Value": 6, "DisplayName": "IES1", "Description": "Relative losses are within ±20 % of the value defined by the RPDS" }, { "Value": 7, "DisplayName": "IES2", "Description": "Relative losses are smaller than 20 % of the value defined by the RPDS" } ] |
|