The PtProtectionClassAttributesType provides the asset attributes describing the protection class and is formally defined in Table 152.
Table 152 – PtProtectionClassAttributesType Definition
Attribute |
Value |
||||
BrowseName |
PtProtectionClassAttributesType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the PtCommonAssetAttributesType defined in chapter 7.11 |
|||||
0:HasComponent |
Variable |
IpClass |
0:UInt16 |
0:MultiStateValueDiscreteType |
O, RO |
0:HasProperty |
Variable |
ExClass |
0:String |
0:PropertyType |
O, RO |
Conformance Units |
|||||
Powertrain Attributes Information |
IpClass provides the degree of protection provided by the enclosure (according to DIN EN 60529). The values of the MultiStateValueDiscreteType variable are defined in Table 153 and shall be used. The values 0-199 are reserved for future extensions of this specification. The values 200-299 shall be used for vendor-specific extensions of this variable.
Table 153 – PtProtectionClassAttributesType Attribute values for child Nodes
BrowsePath |
Value Attribute |
Description Attribute |
||
|
[ { "Value": 0, "DisplayName": "IP00", "Description": "non-protected / non-protected" }, { "Value": 1, "DisplayName": "IP01", "Description": "non-protected / vertically dripping" }, { "Value": 2, "DisplayName": "IP02", "Description": "non-protected / dripping (15° tilted)" }, { "Value": 3, "DisplayName": "IP10", "Description": "≥ 50 mm diameter / non-protected" }, { "Value": 4, "DisplayName": "IP11", "Description": "≥ 50 mm diameter / vertically dripping" }, { "Value": 5, "DisplayName": "IP12", "Description": "≥ 50 mm diameter / dripping (15° tilted)" }, { "Value": 6, "DisplayName": "IP20", "Description": "≥ 12,5 mm diameter / non-protected" }, { "Value": 7, "DisplayName": "IP21", "Description": "≥ 12,5 mm diameter / vertically dripping" }, { "Value": 8, "DisplayName": "IP22", "Description": "≥ 12,5 mm diameter / dripping (15° tilted)" }, { "Value": 9, "DisplayName": "IP30", "Description": "≥ 2,5 mm diameter / non-protected" }, { "Value": 10, "DisplayName": "IP31", "Description": "≥ 2,5 mm diameter / vertically dripping" }, { "Value": 11, "DisplayName": "IP32", "Description": "≥ 2,5 mm diameter / dripping (15° tilted)" }, { "Value": 12, "DisplayName": "IP33", "Description": "≥ 2,5 mm diameter / spraying" }, { "Value": 13, "DisplayName": "IP40", "Description": "≥ 1,0 mm diameter / non-protected" }, { "Value": 14, "DisplayName": "IP41", "Description": "≥ 1,0 mm diameter / vertically dripping" }, { "Value": 15, "DisplayName": "IP42", "Description": "≥ 1,0 mm diameter / dripping (15° tilted)" }, { "Value": 16, "DisplayName": "IP43", "Description": "≥ 1,0 mm diameter / spraying" }, { "Value": 17, "DisplayName": "IP44", "Description": "≥ 1,0 mm diameter / splashing" }, { "Value": 18, "DisplayName": "IP45", "Description": "≥ 1,0 mm diameter / jetting" }, { "Value": 19, "DisplayName": "IP50", "Description": "dust-protected / non-protected" }, { "Value": 20, "DisplayName": "IP51", "Description": "dust-protected / vertically dripping" }, { "Value": 21, "DisplayName": "IP52", "Description": "dust-protected / dripping (15° tilted)" }, { "Value": 22, "DisplayName": "IP53", "Description": "dust-protected / spraying" }, { "Value": 23, "DisplayName": "IP54", "Description": "dust-protected / splashing" }, { "Value": 24, "DisplayName": "IP55", "Description": "dust-protected / jetting" }, { "Value": 25, "DisplayName": "IP56", "Description": "dust-protected / powerful jetting" }, { "Value": 26, "DisplayName": "IP57", "Description": "dust-protected / temporary immersion" }, { "Value": 27, "DisplayName": "IP58", "Description": "dust-protected / continuous immersion" }, { "Value": 28, "DisplayName": "IP60", "Description": "dust-tight / non-protected" }, { "Value": 29, "DisplayName": "IP61", "Description": "dust-tight / vertically dripping" }, { "Value": 30, "DisplayName": "IP62", "Description": "dust-tight / dripping (15° tilted)" }, { "Value": 31, "DisplayName": "IP63", "Description": "dust-tight / spraying" }, { "Value": 32, "DisplayName": "IP64", "Description": "dust-tight / splashing" }, { "Value": 33, "DisplayName": "IP65", "Description": "dust-tight / jetting" }, { "Value": 34, "DisplayName": "IP66", "Description": "dust-tight / powerful jetting" }, { "Value": 35, "DisplayName": "IP67", "Description": "dust-tight / temporary immersion" }, { "Value": 36, "DisplayName": "IP68", "Description": "dust-tight / continuous immersion" }, { "Value": 37, "DisplayName": "IP69", "Description": "dust-tight / high pressure and temperature water jet" }, { "Value": 38, "DisplayName": "IPX1", "Description": "not defined / vertically dripping" }, { "Value": 39, "DisplayName": "IPX2", "Description": "not defined / dripping (15° tilted)" }, { "Value": 40, "DisplayName": "IPX3", "Description": "not defined / spraying" }, { "Value": 41, "DisplayName": "IPX4", "Description": "not defined / splashing" }, { "Value": 42, "DisplayName": "IPX5", "Description": "not defined / jetting" }, { "Value": 43, "DisplayName": "IPX6", "Description": "not defined / powerful jetting" }, { "Value": 44, "DisplayName": "IPX7", "Description": "not defined / temporary immersion" }, { "Value": 45, "DisplayName": "IPX8", "Description": "not defined / continuous immersion" }, { "Value": 46, "DisplayName": "IP1X", "Description": "≥ 50 mm diameter / not defined" }, { "Value": 47, "DisplayName": "IP2X", "Description": "≥ 12,5 mm diameter / not defined" }, { "Value": 48, "DisplayName": "IP3X", "Description": "≥ 2,5 mm diameter / not defined" }, { "Value": 49, "DisplayName": "IP4X", "Description": "≥ 1,0 mm diameter / not defined" }, { "Value": 50, "DisplayName": "IP5X", "Description": "dust-protected / not defined" }, { "Value": 51, "DisplayName": "IP6X", "Description": "dust-tight / not defined" } ] |
|
The ExClass provides the information to the type of explosive protection (according to DIN EN IEC 60079-0). Value examples:
- Ex ta (Protection by enclosure Ex t, Category 1 EPL a, very high level of protection)
- Ex eb (Increased safety Ex e, Category 2 EPL b, high level of protection)
- Ex ic (Intrinsic safety Ex i, Category 3 EPL c, normal level of protection)