OPC Foundation
  • Documents
  • NodeSets
  • Search
9.6 OperatingMode

Description:Actual operating mode of the TCD.

Table 6 – OperatingModeEnumeration Values

Name

Value

Description

OTHER

0

Operating mode of the TCD is unknown

READY_TO_OPERATE

1

TCD is ready to operate (heating, pump and cooling are switched off)

NORMAL_OPERATION

2

TCD is running in normal operating mode

LEAK_STOPPER

3

TCD is running in leak stopper operating mode

MOULD_EVACUATION

4

TCD is carrying out a mould evacuation process

PRESSURE_RELIEF

5

TCD is carrying out a pressure relief process

COOLING

6

TCD is cooling down to StandbyTemperature and switch off

SAFETY_COOLING

7

TCD is cooling down to SwitchingOffTemperature and switch off

ECO

8

TCD is running in Eco operating mode (energy is saved via the reduced pump speed)

BOOST

9

TCD is running in Boost operating mode (pump runs at maximum possible speed)

Please report errors or issues with the site to webmaster.