10.19 PumpControlMode

Description:Defines to which setpoint or function the pump is controlled. The TypeDefinition is MultiStateValueDiscreteType, so the Properties EnumValues and ValueAsText must be filled with the supported values out of Table 9.

Table 9 – Values for PumpControlMode

EnumValue

ValueAsText

Description

0

NORMAL

Normal Operation: fixed pump rotational speed

1

AUTO

Automatic adjustment of the pump rotational speed

2

SPEED

Speed controlled: the pump is controlled according to the specified nominal value PumpSpeed

3

FLOW

Flow rate controlled: the pump is controlled according to the specified nominal value FlowRate

4

TEMP_DIFF

Temperature difference controlled: the pump is controlled according to the specified nominal value TemperatureDifference

5

PRESS_DIFF

Pressure difference controlled: the pump is controlled according to the specified nominal value PressureDifference

6

BOOST

Boost mode: the pump is operated at the maximum possible rotational pump speed