OPC Foundation
  • Documents
  • NodeSets
  • Search
27.1 HelpOffNormalAlarmType

The HelpOffNormalAlarmType can be used by devices, to inform the client about a Condition that is considered to be not normal. It is a subtype of the OffNormalAlarmType defined in OPC UA Part 9 and adds the Property Helptext to give some additional information to the operator.

image025.png

Figure 19 – HelpOffNormalAlarmType Overview

Table 141 – HelpOffNormalAlarmType Definition

Attribute

Value

BrowseName

HelpOffNormalAlarmType

IsAbstract

False

References

Node Class

BrowseName

DataType

TypeDefinition

Other

Subtype of 0:OffNormalAlarmType defined in OPC UA Part 9

0:HasProperty

Variable

HelpText

0:LocalizedText

0:PropertyType

M

0:HasSubtype

ObjectType

MonitoredParameterAlarmType

Servers can use the Property HelpText also in other server specific alarms which are not derived from OffNormalAlarmType.

Please report errors or issues with the site to webmaster.

Copyright © 2025 - OPC Foundation