6.8 Status

This Property represents the current status of the component. The ComponentStatusEnumeration is defined in Table 2.

Table 2 – ComponentStatusEnumeration Definition

Name

Value

Description

OFFLINE

0

Component is not connected to OPC UA server.

(Will not be set by component it-self, but e.g. by line control providing Information for the component)

IDLE

1

Main switch on, no heating (also timer not running), no movement

PREPARING

2

Heating timer running, heating active, security check, setting, service mode

READY_TO_RUN

3

Temperature for switching drives on reached, drives ready for switching on

MANUAL_RUN

4

Component is running with manually set parameters

CONTROLLED_RUN

5

Component is running with controlled parameters

MALFUNCTION

6

Component has stopped running because of an error (also emergency stop), no re-start possible

MAINTENANCE

7

Component is maintained

Please report errors or issues with the site to webmaster.