Table 25 – PnEquipmentContainerType Definition
Attribute |
Value |
||||
BrowseName |
PnEquipmentContainerType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Modelling Rule |
Subtype of BaseObjectType defined in [OPC 10000-5]. |
|||||
HasComponent |
Object |
<PnEquipments> |
|
BaseObjectType |
Optional Placeholder |
The <PnEquipments> shall have the references and components defined in Table 26 and Table 27.
Table 26 – PnEquipmentContainerType Additional References
Source Path |
Reference Type |
Is Forward |
Target Path |
||||
<PnEquipments> |
0:HasInterface |
True |
|
Table 27 – PnEquipmentContainerType Additional Subcomponents
Source Path |
References |
NodeClass |
BrowseName |
DataType TypeDefinition |
Others |
Applied from IPnEquipmentType |
|||||
<PnEquipments> |
0:HasComponent |
Object |
Interfaces |
PnInterfaceContainerType |
M |
<PnEquipments> |
0:HasComponent |
Object |
Modules |
PnRealModuleContainerType |
O |
<PnEquipments> |
0:HasComponent |
Object |
Assets |
PnAssetContainerType |
O |
<PnEquipments> |
0:HasComponent |
Object |
IM |
PnIdentificationType |
O |
<PnEquipments> |
0:HasProperty |
Variable |
Vendor |
StringPropertyType |
O |
<PnEquipments> |
0:HasComponent |
Variable |
Diagnosis |
PnDeviceDiagnosisDataType[]BaseDataVariableType |
O |
<PnEquipments> |
0:HasComponent |
Object |
Alarms |
FolderType |
O |
<PnEquipments> |
0:HasComponent |
Method |
ShowLocation |
ShowLocationMethod |
O |
<PnEquipments> |
0:GeneratesEvent |
ObjectType |
PnDiagnosisAlarmType |
|
|
<PnEquipments> |
0:GeneratesEvent |
ObjectType |
PnAssetChangedEventType |
|
|
Mapping to PROFINET properties:
BrowseName |
Method |
Source |
<PnEquipments> |
DCP |
List of IdentifyResBlock |