The RioFaAnalogInputChannelType provides access to the data of an analog RIO Input Channel according to RIOforFA.
Table 37 – RioFaAnalogInputChannelType
Attribute |
Value |
||||
BrowseName |
RioFaAnalogInputChannelType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the RioChannelType. |
|||||
0:HasComponent |
Variable |
ProcessValue |
RioFaAnalogProcessValueDataType |
RioFaAnalogProcessValueVariableType |
M, RO |
0:HasComponent |
Variable |
SignalValue |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
Config |
RioFaAnalogInputConfigDataType |
RioFaAnalogInputConfigVariableType |
M, RO |
Conformance Units |
|||||
PNRIO Channel Objects |
The ProcessValue Variable contains the current analog Input value for usage by a Controller.
The SignalValue Variable contains the input signal value obtained by reading the input signal through the signal coupling in the Transducer.
The Config Variable contains the configuration properties available for the RIO Channel. See the definition of the RioFaAnalogInputConfigVariableType (see chapter 9.4.6).