OPC Foundation
  • Documents
  • NodeSets
  • Search
7.2.2.6 RioFaAnalogInputChannelType

The RioFaAnalogInputChannelType provides access to the data of an analog RIO Input Channel according to RIOforFA.

Table 37 – RioFaAnalogInputChannelType

Attribute

Value

BrowseName

RioFaAnalogInputChannelType

IsAbstract

False

References

Node Class

BrowseName

DataType

TypeDefinition

Other

Subtype of the RioChannelType.

0:HasComponent

Variable

ProcessValue

RioFaAnalogProcessValueDataType

RioFaAnalogProcessValueVariableType

M, RO

0:HasComponent

Variable

SignalValue

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

Config

RioFaAnalogInputConfigDataType

RioFaAnalogInputConfigVariableType

M, RO

Conformance Units

PNRIO Channel Objects

The ProcessValue Variable contains the current analog Input value for usage by a Controller.

The SignalValue Variable contains the input signal value obtained by reading the input signal through the signal coupling in the Transducer.

The Config Variable contains the configuration properties available for the RIO Channel. See the definition of the RioFaAnalogInputConfigVariableType (see chapter 9.4.6).

Please report errors or issues with the site to webmaster.

Copyright © 2025 - OPC Foundation