This Method sets the Value of the Mode Variable. The security constraints defined in chapter 6.7 apply.

Signature

SetMode (

[in] RioChannelModeEnumeration Mode

);

Argument

Description

Mode

Desired content of the Mode Variable.

The Method Result Codes (defined in Call Service) are defined in Table 33.

Table 33 – Possible Method result codes

Result Code

Description

Good

The Method execution was successful.

Bad_UserAccessDenied

The user has not the right to execute the Method.

Bad_NotSupported

The Server is currently not able to perform the demanded mode change.

Bad_UnexpectedError

The Server is not able to execute the function because an unexpected error occurred. The Device might be temporarily unavailable or unreachable due to network failure.

If the Mode Variable has already the same Value as the argument, the Method shall do nothing and return Good as result code.