Error codes are 4 bytes long, data type being DWORD.
NOTE: Bit 29 in this DWORD value is used to differentiate between error codes defined by OPC Foundation and error codes defined by PLCopen or Vendor.
Field |
Bit Range |
Description |
||||||||||||
Severity |
30:31 |
Indicates whether the ErrorCode represents a good, bad or uncertain condition. These bits have the following meanings:
|
||||||||||||
ErrorType |
29 |
Value 0 indicates OPC error. Please find these error codes in OPC UA 10000-4 specification. Value 1 indicates PLCopen or vendor specific error signaled by BIT28. NOTE: This bit shall always be zero on the wire. |
||||||||||||
ErrorType2 |
28 |
This flag can be evaluated only if BIT29 is Value 1. Value 0 indicates PLCopen error. Value 1 indicates vendor specific error. NOTE 1): This bit shall always be zero on the wire. NOTE 2): This bit shall only be set if bit 29 has value 1, because it is reserved in OPC 10000-4 for future use. |
ErrorCode (Bits 0..27) |
Define |
Description |
Category |
General |
|
16#A000_0001 |
PLCopenUA_Bad_FW_PermanentError |
Internal, permanent error. |
16#A000_0002 |
PLCopenUA_Bad_FW_TempError |
Temp. error; FB could retry to reach FW. |
Category |
Connection |
|
16#A000_0100 |
PLCopenUA_Bad_ConnectionError |
Connection could not be established. |
16#A000_0101 |
PLCopenUA_Bad_HostNotFound |
The requested hostname could not be found. |
16#A000_0102 |
PLCopenUA_Bad_AlreadyConnected |
Connection was already established. |
16#A000_0103 |
PLCopenUA_Bad_SecurityFailed |
Connection failed due to security setup. |
16#A000_0104 |
PLCopenUA_Bad_Suspended |
Connection is suspended. |
16#A000_0105 |
PLCopenUA_Bad_ConnectionInvalidHdl |
Provided ConnectionHdl is not known. |
Category |
Namespace |
|
16#A000_0200 |
PLCopenUA_Bad_NSNotFound |
A namespace with the requested name cannot be found on server. |
Category |
Node |
|
16#A000_0300 |
PLCopenUA_Bad_ResultTooLong |
Target PLC variable is too short for retrieved data. |
16#A000_0301 |
PLCopenUA_Bad_InvalidType |
Invalid or unsupported Type. |
16#A000_0302 |
PLCopenUA_Bad_NodeInvalidHdl |
Provided NodeHdl is not known. |
16#A000_0303 |
PLCopenUA_Bad_MethodInvalidHdl |
Provided MethodHdl is not known. |
16#A000_0304 |
PLCopenUA_Bad_ReadFailed |
Read failed for unknown reason. |
16#A000_0305 |
PLCopenUA_Bad_WriteFailed |
Write failed for unknown reason. |
16#A000_0306 |
PLCopenUA_Bad_CallFailed |
Method Call failed for unknown reason. |
16#A000_0307 |
PLCopenUA_Bad_InParamFailed |
Method Call Input parameter conversion failed. |
16#A000_0308 |
PLCopenUA_Bad_OutParamFailed |
Method Call Output parameter conversion failed. ATTENTION: this means the MethodCall was executed successfully but the returned values could not be converted. |
Category |
Attribute |
|
16#A000_0400 |
PLCopenUA_Bad_AttributeIdUnknown |
Used in UA_NodeGetInformation for elements, which are not in this NodeClass existing. |
16#A000_0401 |
PLCopenUA_Bad_AttributeIdInvalid |
Used in UA_NodeGetInformation for elements, which should exist but don’t. |
Category |
Monitoring |
|
16#A000_0500 |
PLCopenUA_Bad_SubscriptionInvalidHdl |
Provided SubscriptionHdl is not known. |
16#A000_0501 |
PLCopenUA_Bad_MonitoredItemInvalidHdl |
Provided MonitoredItemHdl is not known. |
16#A000_0502 |
PLCopenUA_Bad_MonitoredItemSyncMismatch |
Mixed controller sync and firmware sync in same list |
16#A000_0503 |
PLCopenUA_Bad_SyncModeInvalid |
Sync mode invalid |