The ConductivitySignalType provides ObjectType to add conductivity measurement specific variables. It is formally defined in Table 138.
Table 138 – ConductivitySignalType definition
Attribute |
Value |
||||
BrowseName |
ConductivitySignalType |
||||
IsAbstract |
False |
||||
References |
NodeClass |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of AnalyticalSignalType defined in 7.20, i.e. inheriting the InstanceDeclarations of that Node |
|||||
0:HasComponent |
Object |
<SignalCalibrationIdentifier> |
|
0:BaseObjectType |
OP |
0:HasComponent |
Object |
SignalConditionSet |
|
0:BaseObjectType |
O |
Conformance Units |
|||||
PA-DIM ConductivitySignalType |
|||||
PA-DIM ConductivitySignalType SensorCleaningsCounter |
|||||
PA-DIM ConductivitySignalType SensorSterilisationsCounter |
<SignalCalibrationIdentifier> is a container object for the calibration parameters of the signal. It is inherited from AnalogSignalType and has an additional interface reference to IConductivityCalibrationType to add conductivity signal specific calibration variables. Since it is a placeholder, an instance of ConductivitySignalType can have several calibration objects.
SignalConditionSet is a container object for the condition parameters of the signal. It is inherited from AnalogSignalType and has an additional interface reference to IConductivitySignalConditionSetType to add conductivity signal specific condition variables.
The components of ConductivitySignalType have additional references which are defined in Table 139.
Table 139 – ConductivitySignalType additional References
SourceBrowsePath |
Reference Type |
Is Forward |
TargetBrowsePath |
||||
<SignalCalibrationIdentifier> |
0:HasInterface |
True |
IConductivityCalibrationType |
||||
|
0:HasDictionaryEntry |
True |
|||||
SignalConditionSet |
0:HasInterface |
True |
IConductivitySignalConditionSetType |
||||
|
0:HasDictionaryEntry |
True |
The components of ConductivitySignalType have additional subcomponents which are defined in Table 140.
Table 140 – ConductivitySignalType additional subcomponents
BrowsePath |
References |
NodeClass |
BrowseName |
DataType |
TypeDefinition |
Others |
<SignalCalibrationIdentifier> |
0:HasComponent |
Variable |
ConductivityCellConstant |
0:Float |
0:AnalogUnitType |
O |
SignalConditionSet |
0:HasComponent |
Variable |
ConductivityMeasuringMethod |
0:UInt32 |
0:MultiStateDictionaryEntryDiscreteType |
O |
SignalConditionSet |
0:HasComponent |
Variable |
SensingElementTemperature |
0:Float |
0:AnalogUnitType |
O |
SignalConditionSet |
0:HasComponent |
Variable |
TemperatureCompensationStyle |
0:UInt32 |
0:MultiStateDictionaryEntryDiscreteType |
O |
SignalConditionSet |
0:HasProperty |
Variable |
SensorCleaningsCounter |
0:UInt32 |
0:PropertyType |
O |
SignalConditionSet |
0:HasProperty |
Variable |
SensorSterilisationsCounter |
0:UInt32 |
0:PropertyType |
O |
The child Nodes of the ConductivitySignalType have additional Attribute values defined in Table 141.
Table 141 – ConductivitySignalType Attribute values for child Nodes
BrowsePath |
Value Attribute |
|||
|
0.0 |
|||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefactUnitId: 4536624DisplayName: cm⁻¹Description: reciprocal centimetre |
|||
|
0 |
|||
|
ns=3;s=0112/2///61987#ABP721#001 |
|||
|
inductive |
|||
|
0.0 |
|||
|
0 |
|||
|
ns=3;s=0112/2///61987#ABP724#001 |
|||
|
no temperature compensation |
|||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefactUnitId: 4408652DisplayName: °CDescription: degree Celsius |
|||
|
0 |
|||
|
0 |