The TocSignalType provides ObjectType to add TOC measurement specific variables. It is formally defined in Table 114.
Table 114 – TocSignalType definition
Attribute |
Value |
||||
BrowseName |
TocSignalType |
||||
IsAbstract |
False |
||||
References |
NodeClass |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of AnalyticalSignalType defined in 7.20, i.e. inheriting the InstanceDeclarations of that Node |
|||||
0:HasComponent |
Object |
SignalConditionSet |
|
0:BaseObjectType |
O |
Conformance Units |
|||||
PA-DIM TocSignalType |
|||||
PA-DIM TocSignalType ChopperFrequencyDeviation |
|||||
PA-DIM TocSignalType RelativeReagentLevel |
|||||
PA-DIM TocSignalType AbsoluteSampleGasPressure |
|||||
PA-DIM TocSignalType SampleGasVolumeFlow |
SignalConditionSet is a container object for the condition parameters of the signal. It is inherited from AnalogSignalType and has an additional interface reference to ITocSignalConditionSetType to add TOC signal specific condition variables.
The components of TocSignalType have additional references which are defined in Table 115.
Table 115 – TocSignalType additional References
SourceBrowsePath |
Reference Type |
Is Forward |
TargetBrowsePath |
|||
SignalConditionSet |
0:HasInterface |
True |
ITocSignalConditionSetType |
|||
|
0:HasDictionaryEntry |
True |
||||
|
0:HasDictionaryEntry |
True |
||||
|
0:HasDictionaryEntry |
True |
||||
|
0:HasDictionaryEntry |
True |
||||
|
0:HasDictionaryEntry |
True |
||||
|
0:HasDictionaryEntry |
True |
The components of TocSignalType have additional subcomponents which are defined in Table 116.
Table 116 – TocSignalType additional subcomponents
BrowsePath |
References |
NodeClass |
BrowseName |
DataType |
TypeDefinition |
Others |
SignalConditionSet |
0:HasComponent |
Variable |
ChopperFrequencyDeviation |
0:Float |
0:BaseAnalogType |
O |
SignalConditionSet |
0:HasComponent |
Variable |
RelativeReagentLevel |
0:Float{Any} |
0:AnalogUnitType |
O |
SignalConditionSet |
0:HasComponent |
Variable |
SampleCellTemperature |
0:Float |
0:AnalogUnitType |
O |
SignalConditionSet |
0:HasComponent |
Variable |
DetectorZeroSignal |
0:Float |
0:AnalogUnitType |
O |
SignalConditionSet |
0:HasProperty |
Variable |
SourceResidualLife |
0:Float |
0:PropertyType |
O |
SignalConditionSet |
0:HasComponent |
Variable |
AbsoluteSampleGasPressure |
0:Float |
0:AnalogUnitType |
O |
SignalConditionSet |
0:HasComponent |
Variable |
SampleGasVolumeFlow |
0:Float |
0:AnalogUnitType |
O |
The child Nodes of the TocSignalType have additional Attribute values defined in Table 117.
Table 117 – TocSignalType Attribute values for child Nodes
BrowsePath |
Value Attribute |
|||
|
0.0 |
|||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefactUnitId: 20529DisplayName: % or pctDescription: percent |
|||
|
0.0 |
|||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefactUnitId: 20529DisplayName: % or pctDescription: percent |
|||
|
0.0 |
|||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefactUnitId: 4408652DisplayName: °CDescription: degree Celsius |
|||
|
0.0 |
|||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefactUnitId: 13625DisplayName: ppmDescription: part per million |
|||
|
1.0 |
|||
|
0.0 |
|||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefactUnitId: 5063250DisplayName: mbarDescription: millibar |
|||
|
0.0 |
|||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefactUnitId: 4535090DisplayName: l/hDescription: litre per hour |