The IAmperometricSignalConditionSetType provides the interface to amperometric measurement signal specific condition variables and is formally defined in Table 67.

Table 67 – IAmperometricSignalConditionSetType definition

Attribute

Value

BrowseName

IAmperometricSignalConditionSetType

IsAbstract

True

References

NodeClass

BrowseName

DataType

TypeDefinition

Other

Subtype of 0:BaseInterfaceType defined in OPC 10000-5, i.e. inheriting the InstanceDeclarations of that Node

0:HasComponent

Variable

SensingElementTemperature

0:Float

0:AnalogUnitType

O

0:HasComponent

Variable

SensorNextCalibration

0:UInt32

0:AnalogUnitType

O

0:HasProperty

Variable

SensorCleaningsCounter

0:UInt32

0:PropertyType

O

0:HasProperty

Variable

SensorSterilisationsCounter

0:UInt32

0:PropertyType

O

Conformance Units

PA-DIM AmperometricSignalType

PA-DIM AmperometricSignalType SensorNextCalibration

PA-DIM AmperometricSignalType SensorCleaningsCounter

PA-DIM AmperometricSignalType SensorSterilisationsCounter

SensingElementTemperature is defined by IRDI as ABP565#001 which states “temperature measured at a sensing element”.

SensorNextCalibration is defined by IRDI as ABP566#001 which states “time that can elapse until the next calibration, calculated from the configured calibration interval or estimated by the device”.

SensorCleaningsCounter is defined by IRDI as ABP546#001 which states “number of times a sensor has been cleaned in place”.

SensorSterilisationsCounter is defined by IRDI as ABP547#001 which states “number of times a sensor has been sterilized in place”.

The components of IAmperometricSignalConditionSetType have additional references which are defined in Table 68.

Table 68 – IAmperometricSignalConditionSetType additional References

SourceBrowsePath

Reference Type

Is Forward

TargetBrowsePath

SensingElementTemperature

0:HasDictionaryEntry

True

3:0112/2///61987#ABP565#001

SensingElementTemperature

0:EngineeringUnits

0:HasDictionaryEntry

True

3:0112/2///61987#ABA968#002

SensorNextCalibration

0:HasDictionaryEntry

True

3:0112/2///61987#ABP566#001

SensorNextCalibration

0:EngineeringUnits

0:HasDictionaryEntry

True

3:0112/2///61987#ABA968#002

SensorCleaningsCounter

0:HasDictionaryEntry

True

3:0112/2///61987#ABP546#001

SensorSterilisationsCounter

0:HasDictionaryEntry

True

3:0112/2///61987#ABP547#001

The child Nodes of the IAmperometricSignalConditionSetType have additional Attribute values defined in Table 69.

Table 69 – IAmperometricSignalConditionSetType Attribute values for child Nodes

BrowsePath

Value Attribute

SensingElementTemperature

0.0

SensingElementTemperature

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefactUnitId: 4408652DisplayName: °CDescription: degree Celsius

SensorNextCalibration

0

SensorNextCalibration

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefactUnitId: 4473177DisplayName: dDescription: day

SensorCleaningsCounter

0

SensorSterilisationsCounter

0