ZeroPointAdjustment is a method used to initiate an automatic adjustment cycle to determine the zero point of a process variable. The adjustment procedure starts after the method has been called and ends automatically, when it has been finished. The method does not have any arguments. The adjustment procedure is device-specific.
Signature
ZeroPointAdjustment (
);
Method Result Codes are defined in Table 51.
Table 51 - ZeroPointAdjustment Method Result Codes
Result Code |
Description |
Bad_UserAccessDenied |
The current user does not have the rights required. |
Table 52 specifies the AddressSpace representation for the ZeroPointAdjustment Method.
Table 52 - ZeroPointAdjustment Method AddressSpace definition
Attribute |
Value |
||||
BrowseName |
ZeroPointAdjustment |
||||
References |
NodeClass |
BrowseName |
DataType |
TypeDefinition |
Modelling Rule |