If MultiStateDictionaryEntryDiscreteType Variables reference an IEC 61987 CDD PROPERTY with a Value list, the following mapping applies:
- For each possible element in the "Value list" map the Preferred name of the element to the „EnumValues“ Property.
- For each possible element in the "Value list" map the IRDI of the element to the „EnumDictionaryEntries“ Property.
An example for the SensorConnection Property with IRDI 0112/2///61987#ABB091#002 is in Table 26:
Table 26 - Example of a MultiStateDictionaryEntryDiscreteType with CDD reference
IEC 61987 CDD |
ecl@ss |
OPC UA mapping |
|
„Value list“ attribute |
„Value list“ attributeto be defined |
„EnumValues“ Property |
„EnumDictionaryEntries“ Property |
0112/2///61987#ABL113 - 4-wire |
0173-1#02-CCCnnn#00n |
[0] "4-wire" |
[0] 3:0112/2///61987#ABL113#001 |
0112/2///61987#ABL114 - 3-wire |
0173-1#02-CCCnnn#00n |
[1] "3-wire" |
[1] 3:0112/2///61987#ABL114#001 |
0112/2///61987#ABL115 - 2-wire |
0173-1#02-CCCnnn#00n |
[2] "2-wire" |
[2] 3:0112/2///61987#ABL115#001 |
0112/2///61987#ABI407 – others |
0173-1#02-CCCnnn#00n |
[3] "others" |
[3] 3:0112/2///61987#ABI407#004 |