The MonitoringType provides entry points for monitoring a MachineryItem and is formally defined in Table 40.

Table 40 – MonitoringType Definition

Attribute

Value

BrowseName

MonitoringType

IsAbstract

False

Description

Entry point for monitoring information of a MachineryItem.

References

Node Class

BrowseName

DataType

TypeDefinition

Other

Subtype of the 0:FolderType

0:HasProperty

Variable

0:DefaultInstanceBrowseName

0:QualifiedName

0:PropertyType

-

HasComponent

Object

Status

FolderType

O

HasComponent

Object

Health

FolderType

O

HasComponent

Object

Process

FolderType

O

HasComponent

Object

Consumption

FolderType

O

Conformance Units

Machinery Monitoring

The child Nodes of the MonitoringType have additional Attribute values defined in Table 41.

Table 41 – MonitoringType Attribute values for child Nodes

BrowsePath

Value Attribute

Description Attribute

0:DefaultInstanceBrowseName

Monitoring

The default BrowseName for instances of the type.

Status

-

Entry point for status information of the MachineryItem. If this Object is provided, and the MachineryItemState is provided, it shall be referenced. If this Object is provided and the MachineryOperationMode is provided, it shall be referenced.

Health

-

Entry point of health information of the MachineryItem.

Process

-

Entry point for process information of the MachineryItem.

Consumption

Entry point for consumption information of the MachineryItem.

The components of the MonitoringType have additional subcomponents which are defined in Table 42.

Table 42 – MonitoringType Additional Subcomponents

Source Path

Reference

Node Class

BrowseName

DataType

TypeDefinition

Others

Status

0:HasComponent

Object

MachineryItemState

MachineryItemState_StateMachineType

O

Status

0:HasComponent

Object

OperationMode

MachineryOperationModeStateMachineType

O

Status

0:HasComponent

Object

Stacklight

3:BasicStacklightType

O

Health

0:HasComponent

Object

2:DeviceHealthAlarms

0:FolderType

O

Health

0:HasComponent

Variable

2:DeviceHealth

2:DeviceHealthEnumeration

0:BaseDataVariableType

O

The components of the MonitoringType have additional References which are defined in Table 43.

Table 43 – MonitoringType Additional References

SourceBrowsePath

Reference Type

Is Forward

TargetBrowsePath

Health

0:HasInterface

True

2:IDeviceHealthType