This chapter defines the corresponding Conformance Units for the OPC UA Information Model for Machinery – Energy Management.
Table 13 – Conformance Units for Machinery – Energy Management
Category |
Title |
Description |
Server |
Machinery Energy Base Structure |
Supports at least one MachineryItem supporting the Consumption Object having at least one sub-folder following the predefined BrowseNames of this specification. |
Server |
Machinery Energy Main grouping |
Each MachineryItem supporting the Consumption Object with a sub-folder according to this specification provides a Main Object of EnergyMeasurementType for each of those sub-folders. |
Server |
Machinery Energy Non Electrical Base |
Supports INonElectricalEnergyType and at least one instance of EnergyMeasurementType implementing the interface. |
Server |
Machinery Energy Non Electrical Mass Flow |
Supports IBaseFlowType, IMassFlowType and at least one instance of EnergyMeasurementType implementing IMassFlowType. |
Server |
Machinery Energy Non Electrical Volume Flow |
Supports IBaseFlowType, IVolumeFlowType and at least one instance of EnergyMeasurementType implementing IVolumeFlowType. |
Server |
Machinery Energy Contains |
Supports the Contains ReferenceType and at least one instance using the ReferenceType. |
Table 14 lists all Profiles defined in this document and defines their URIs.
Table 14 – Profile URIs for OPC UA for Machinery – Energy Management
Profile |
URI |
Machinery Energy Base Server Facet |
http://opcfoundation.org/UA-Profile/Machinery/Energy/Server/Base |
The following sections specify the Facets available for Servers that implement the OPC UA for Machinery – Energy Management companion specification. Each section defines and describes a Facet or Profile.
Table 15 defines a Profile that describes the base functionality to provide energy consumption information of a MachineryItem.
Table 15 – Machinery Energy Base Server Facet
Group |
Conformance Unit / Profile Title |
Mandatory / Optional |
Profile |
Machinery Monitoring Server Facet |
|
ECM |
ECM Energy Measurement |
M |
ECM |
ECM EnergyProfile E0 |
O |
ECM |
ECM EnergyProfile E1 |
O |
ECM |
ECM EnergyProfile E2 |
O |
ECM |
ECM EnergyProfile E3 |
O |
ECM |
ECM EnergyProfile D0 |
O |
ECM |
ECM EnergyProfile D1 |
O |
ECM |
ECM Energy Measurement Common DataTypes |
O |
ECM |
ECM Accuracy Domain Percent full scale |
O |
ECM |
ECM Accuracy Domain Percent actual reading |
O |
ECM |
ECM Accuracy Domain IEC |
O |
ECM |
ECM Accuracy Domain EN |
O |
Machinery Energy |
Machinery Energy Base Structure |
M |
Machinery Energy |
Machinery Energy Main grouping |
O |
Machinery Energy |
Machinery Energy Non Electrical Base |
O |
Machinery Energy |
Machinery Energy Non Electrical Mass Flow |
O |
Machinery Energy |
Machinery Energy Non Electrical Volume Flow |
O |
Machinery Energy |
Machinery Energy Contains |
O |
This specification does not define client facets.