The LaserSystemOperationCounterType gives an overview of how long the system has been in use.
The LaserSystemOperationCounterType is formally defined in Table 21.
Table 21 – LaserSystemOperationCounterType Definition
Attribute |
Value |
||||
BrowseName |
LaserSystemOperationCounterType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 3:MachineryOperationCounterType defined in OPC 40001-1 i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasProperty |
Variable |
2:PowerOnDuration |
0:Duration |
0:PropertyType |
M, RO |
0:HasProperty |
Variable |
2:OperationDuration |
0:Duration |
0:PropertyType |
M, RO |
0:HasProperty |
Variable |
0:DefaultInstanceBrowseName |
0:QualifiedName |
0:PropertyType |
|
0:HasInterface |
ObjectType |
2:IOperationCounterType |
|
|
|
Conformance Units |
|||||
LaserSystems LaserSystemOperationCounterType Basic |
|||||
3:Machinery Operation Counter |
The mandatory 2:PowerOnDuration is the duration the laser system has been powered on. It shall be used as defined by OPC 10000-100.
The mandatory 2:OperationDuration is the duration in which the laser system has actively emitted radiation, This, for example, is not the case if radiation is only caused by a trickle current.
Note: Incrementing the above two variables in a minute interval is deemed sufficient.
Note: The definition for the above two variable is intentionally vague and may differ from manufacturer to manufacturer.