This structure represents the measurement values of phases relative to neutral, for example for current or voltage.
Phase names L1, L2, L3 can also be seen as A, B, C according to IEC 61557-12 [4].
AcPeDataType corresponds to the magnitude values for phsA, phsB, phsC data objects within a WYE Common Data Class as defined by IEC 61850-7-3 [7].
Table 45 – AcPeDataType Structure
Name |
Type |
Description |
AcPeDataType |
Structure |
|
L1 |
0:Float |
Phase L1-N (or phase a-n) |
L2 |
0:Float |
Phase L2-N (or phase b-n) |
L3 |
0:Float |
Phase L3-N (or phase c-n) |
Its representation in the AddressSpace is defined in Table 46.
Table 46 – AcPeDataType Definition
Attribute |
Value |
|||||
BrowseName |
AcPeDataType |
|||||
IsAbstract |
False |
|||||
References |
NodeClass |
BrowseName |
DataType |
TypeDefinition |
Other |
|
Subtype of the 0:Structure |
||||||
Conformance Units |
||||||
ECM EnergyProfile E0 |
||||||
ECM EnergyProfile E3 |
||||||
ECM Energy Measurement Common DataTypes |