This structure represents the measurement values of phases relative to neutral, for example for current or voltage.

Phase names L1, L2, L3 can also be seen as A, B, C according to IEC 61557-12 [4].

AcPeDataType corresponds to the magnitude values for phsA, phsB, phsC data objects within a WYE Common Data Class as defined by IEC 61850-7-3 [7].

Table 45 – AcPeDataType Structure

Name

Type

Description

AcPeDataType

Structure

L1

0:Float

Phase L1-N (or phase a-n)

L2

0:Float

Phase L2-N (or phase b-n)

L3

0:Float

Phase L3-N (or phase c-n)

Its representation in the AddressSpace is defined in Table 46.

Table 46 – AcPeDataType Definition

Attribute

Value

BrowseName

AcPeDataType

IsAbstract

False

References

NodeClass

BrowseName

DataType

TypeDefinition

Other

Subtype of the 0:Structure

Conformance Units

ECM EnergyProfile E0

ECM EnergyProfile E3

ECM Energy Measurement Common DataTypes